Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/96176
Title: | Analysis of the grounding for the substation under very fast transient using improved lossy thin-wire model for FDTD | Authors: | Chen, H Du, Y Yuan, M Liu, QH |
Issue Date: | Dec-2018 | Source: | IEEE transactions on electromagnetic compatibility, Dec. 2018, v. 60, no. 6, p. 1833-1841 | Abstract: | A thin-wire model of conductors with arbitrary cross sections for a finite-difference time-domain (FDTD) method is proposed for the study of lightning transients in electrical systems. The proposed thin-wire model considers both the frequency-dependent characteristics of the wires and the influences of the surrounding media. The model represents a wire using four FDTD cells with an equivalent side length and modified material parameters. A rational equivalent circuit is added at the center edge of the FDTD cells to represent the internal impedance of the wire. An analytical formula for determining the equivalent side length and the modified material parameters of the FDTD cells are also presented. The proposed formula gives a new prospect to build the thin-wire model in FDTD. In this model, the equivalent side length can be set arbitrarily and much larger than the original wire, which can greatly reduce the computation time. Meanwhile, the method can be extended to the thin-wire structure with arbitrary cross sections. The model is verified with various measurements. Finally, a practical grounding grid of a substation with external water supply is analyzed. | Keywords: | Finite-difference time domain (FDTD) Grounding grid Lightning Skin effect Substation |
Publisher: | Institute of Electrical and Electronics Engineers | Journal: | IEEE transactions on electromagnetic compatibility | ISSN: | 0018-9375 | EISSN: | 1558-187X | DOI: | 10.1109/TEMC.2018.2807123 | Rights: | © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The following publication H. Chen, Y. Du, M. Yuan and Q. H. Liu, "Analysis of the Grounding for the Substation Under Very Fast Transient Using Improved Lossy Thin-Wire Model for FDTD," in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 6, pp. 1833-1841, Dec. 2018 is available at https://doi.org/10.1109/TEMC.2018.2807123. |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Chen_Analysis_Grounding_Substatiunder.pdf | Pre-Published version | 1.39 MB | Adobe PDF | View/Open |
Page views
62
Last Week
0
0
Last month
Citations as of Oct 13, 2024
Downloads
43
Citations as of Oct 13, 2024
SCOPUSTM
Citations
9
Citations as of Oct 17, 2024
WEB OF SCIENCETM
Citations
10
Citations as of Oct 17, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.