Abstract: Background: Dyop® is a dynamic optotype with a rotating and segmented visual stimulus. It can be used for visual acuity and refractive error measurement. The objective of the study was to compare refractive error measurement using the Dyop® acuity and LogMAR E charts.
Methods: Fifty subjects aged 18 or above with aided visual acuity better than 6/12 were recruited. Refractive error was measured by subjective refraction methods using the Dyop® acuity chart and LogMAR E charts and the duration of measurement compared. Thibo’s notation was used to represent the refractive error obtained for analysis.
Results: There was no significant difference in terms of spherical equivalent (M) (P=0.96) or J0 (P=0.78) and J45 (P=0.51) components measured using the Dyop® acuity and LogMAR E charts. However, subjective refraction measurement was significantly faster using the Dyop® acuity chart (t=4.46, P<0.05), with an average measurement time of 419.90±91.17 versus 452.04±74.71 seconds using the LogMAR E chart.
Conclusions: Accuracy of refractive error measurement using a Dyop® chart was comparable with use of a LogMAR E chart. The dynamic optotype Dyop® could be considered as an alternative fixation target to be used in subjective refraction.
Keywords: Dyop
Dynamic optotype
Visual acuity
Subjective refraction
Publisher: AME Publishing Company
Journal: Annals of eye science 
EISSN: 2520-4122
DOI: 10.21037/aes-22-17
Rights: Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) (https://creativecommons.org/licenses/by-nc-nd/4.0/)
The following publication Sum, R. W., & Woo, G. C. (2022). Subjective refractions determined by Dyop ® and LogMAR chart as fixation targets. Annals of Eye Science, v.7 is available at https://dx.doi.org/10.21037/aes-22-17
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
6960-PB12-1704-R2.pdf828.86 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

97
Last Week
0
Last month
Citations as of May 11, 2025

Downloads

46
Citations as of May 11, 2025

WEB OF SCIENCETM
Citations

2
Citations as of Jun 5, 2025

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.