Title: Effects of frontal area density on outdoor thermal comfort and air quality
Authors: Li, Z 
Zhang, H 
Wen, CY 
Yang, AS
Juan, YH
Issue Date: Aug-2020
Source: Building and environment, Aug. 2020, v. 180, 107028
Abstract: This paper systematically investigates the effects of the frontal area density of various three-dimensional (3D) array building models on the thermal comfort and air quality at the pedestrian level above four sidewalks (north, south, east and west). The buoyancy force for natural-convection flows and the realistic solar irradiance at local solar times (LSTs) from 0700 to 1700 are considered with five different frontal area densities (λF = 0.0825–1.25). By a combination of the Rayman model and the ANSYS Fluent® software, the CO concentration and physiologically equivalent temperature (PET) are solved numerically. The simulated CO concentration and PET results are considered as outdoor parameters of the air quality and thermal comfort. A critical λF is obtained for urban development by applying multivariable regression analysis to a group of dimensionless parameters. This analysis will facilitate the choice of building density and simultaneously enhance the air quality and thermal comfort. The results reveal that with an increase in λF, the PET decreases above most of sidewalks during the daytime, while only is a steady reduction of air quality observed above west and east sidewalks of spanwise streets. According to the multivariable regression analysis for Hong Kong, the building density should have a λF value between 0.82 and 0.84 to basically realize a PET <38 °C and CO concentration <30000 μg/m3 simultaneously in the daytime in June.
Keywords: Air quality
Computational fluid dynamics
Frontal area density
Outdoor thermal comfort
Realistic solar radiation
Publisher: Pergamon Press
Journal: Building and environment 
ISSN: 0360-1323
EISSN: 1873-684X
DOI: 10.1016/j.buildenv.2020.107028
Rights: © 2020 Elsevier Ltd. All rights reserved.
© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Li, Z., Zhang, H., Wen, C. Y., Yang, A. S., & Juan, Y. H. (2020). Effects of frontal area density on outdoor thermal comfort and air quality. Building and Environment, 180, 107028 is available at https://doi.org/10.1016/j.buildenv.2020.107028.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Li_Effects_Frontal_Area.pdfPre-Published version2.96 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

86
Last Week
0
Last month
Citations as of Apr 14, 2025

Downloads

166
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

70
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

47
Citations as of Oct 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.