Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/89289
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Rehabilitation Sciencesen_US
dc.contributorDepartment of Health Technology and Informaticsen_US
dc.creatorMiller, Ten_US
dc.creatorYing, MTCen_US
dc.creatorHung, VWYen_US
dc.creatorTsang, CSLen_US
dc.creatorOuyang, Hen_US
dc.creatorChung, RCKen_US
dc.creatorQin, Len_US
dc.creatorPang, MYCen_US
dc.date.accessioned2021-03-05T07:39:18Z-
dc.date.available2021-03-05T07:39:18Z-
dc.identifier.issn8756-3282en_US
dc.identifier.urihttp://hdl.handle.net/10397/89289-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rights© 2020 Elsevier Inc. All rights reserveden_US
dc.rights© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.en_US
dc.rightsThe following publication Miller, T., Ying, M. T. C., Hung, V. W. Y., Tsang, C. S. L., Ouyang, H., Chung, R. C. K., Qin, L., & Pang, M. Y. C. (2021). Determinants of estimated failure load in the distal radius after stroke: An HR-pQCT study. Bone, 144, 115831 is available at https://dx.doi.org/10.1016/j.bone.2020.115831.en_US
dc.subjectFailure loaden_US
dc.subjectHR-pQCTen_US
dc.subjectRadiusen_US
dc.subjectStrokeen_US
dc.titleDeterminants of estimated failure load in the distal radius after stroke : an HR-pQCT studyen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume144en_US
dc.identifier.doi10.1016/j.bone.2020.115831en_US
dcterms.abstractBone health is often compromised after stroke and the distal radius is a common site of fragility fractures. The macro- and mircoproperties of bone tissue after stroke and their clinical correlates are understudied. The objectives of the study were to use High-Resolution peripheral Quantitative Computed Tomography (HR-pQCT) to investigate the bone properties at the distal radius, and to identify the correlates of estimated failure load for the distal radius in people with chronic stroke. This was a cross-sectional study of 64 people with stroke (age: 60.8 ± 7.7 years, stroke duration: 5.7 ± 3.9 years) and 64 age- and sex-matched controls. Bilateral bone structural, densitometric, geometric and strength parameters of the distal radius were measured using HR-pQCT. The architecture, stiffness and echo intensity of the bilateral biceps brachii muscle and brachial artery blood flow were evaluated using diagnostic ultrasound. Other outcomes included the Fugl-Meyer Motor Assessment (FMA), Motor Activity Log (MAL), and Composite Spasticity Scale (CSS). The results revealed a significant side (paretic vs non-paretic for the stroke group, non-dominant vs dominant for controls) by group (stroke vs control) interaction effect for estimated failure load, cortical area, cortical thickness, trabecular number and trabecular separation, and all volumetric density parameters. Post-hoc analysis showed percent side-to-side differences in bone outcomes were greater in the stroke group than the control group, with the exception of trabecular thickness and intracortical porosity. Among the HR-pQCT variables, percent side-to-side difference in trabecular volumetric bone mineral density contributed the most to the percent side-to-side difference in estimated failure load in the stroke group (R2 change = 0.334, β = 1.106). Stroke-related impairments (FMA, MAL, CSS) were found to be significant determinants of the percent side-to-side difference in estimated failure load (R2 change = 0.233, β = −0.480). This was the first study to examine bone microstructure post-stroke. We found that the paretic distal radius had compromised bone structural properties and lower estimated failure load compared to the non-paretic side. Motor impairment was a determinant of estimated bone strength at the distal radius and may be a potential intervention target for improving bone health post-stroke.en_US
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationBone, Mar. 2021, v. 144, 115831en_US
dcterms.isPartOfBoneen_US
dcterms.issued2021-03-
dc.identifier.scopus2-s2.0-85098639893-
dc.identifier.artn115831en_US
dc.description.validate202103 bcvcen_US
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumbera0590-n48-
dc.identifier.SubFormID372-
dc.description.fundingSourceRGCen_US
dc.description.fundingTextP0005633en_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Miller_Determinants_Distal_Radius.pdfPre-Published version1.51 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

100
Last Week
1
Last month
Citations as of Apr 21, 2024

Downloads

59
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

4
Citations as of Apr 26, 2024

WEB OF SCIENCETM
Citations

3
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.