Title: Feasibility of controlling prosthetic hand using sonomyography signal in real time : preliminary study
Authors: Shi, J
Chang, Q
Zheng, YP 
Issue Date: 2010
Source: Journal of rehabilitation research and development, 2010, v. 47, no. 2, p. 87-98
Abstract: The morphological changes of muscle can be accurately detected by sonography, a process we have termed sonomyography (SMG). This article investigates the feasibility of using muscle thickness deformation SMG as a new signal source to control a prosthetic hand in real time. Thickness deformation SMG of the extensor muscle was measured by a block-matching algorithm during wrist extension-flexion; the amplitude of the deformation was used to control the prosthetic hand. We compared various fast-search algorithms to select the best one for real-time prosthetic control. The two-dimensional logarithmic search (TDL) algorithm, with and without streaming single-instruction multiple-data extensions, showed excellent execution efficiency, with an overall mean correlation coefficient of about 0.99, a mean standard root-mean-square error <0.75, and a mean relative root-mean-square error <8.0% referenced to the cross-correlation algorithm baseline. The mean frame rates were greater than the ultrasound sampling rate (12 Hz), indicating that TDL could be implemented in real-time control. These results demonstrate that only one muscle position is needed to control a prosthetic hand, allowing for proprioception of muscle tension, and that the SMG provides good control of the prosthetic hand, allowing it to proportionally open and close with a fast-search algorithm.
Keywords: Block-matching algorithm
Electromyography
Prosthetic control
Prosthetic hand
Real time
Skeletal muscle
Sonomyography
Streaming SIMD extensions
Two-dimensional logarithmic search
Ultrasound
Publisher: U.S. Department of Veterans Affairs, Rehabilitation Research and Development Service
Journal: Journal of rehabilitation research and development 
ISSN: 0748-7711
DOI: 10.1682/JRRD.2009.03.0031
Rights: The article is available at http://www.rehab.research.va.gov/jour/10/472/absshi.html
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Shi_Prosthetic_Hand_Sonomyography.pdf549.93 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

344
Last Week
1
Last month
Citations as of Dec 22, 2024

Downloads

267
Citations as of Dec 22, 2024

SCOPUSTM   
Citations

20
Last Week
0
Last month
0
Citations as of Dec 19, 2024

WEB OF SCIENCETM
Citations

27
Last Week
0
Last month
0
Citations as of Dec 19, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.