Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/109178
PIRA download icon_1.1View/Download Full Text
Title: Mitigating inter-story drift concentration in seismic-resistant self-centering braced frames by using strong backup systems
Authors: Huang, J 
Zhu, S 
Issue Date: 2024
Source: Bulletin of earthquake engineering, Latest articles, Published: 04 September 2024, https://doi.org/10.1007/s10518-024-01997-8
Abstract: Seismic-resistant self-centering concentrically braced frames (SC-CBFs) are susceptible to the concentration of inter-story drifts during earthquakes owing to the relatively low energy dissipation ability of braces. To address this limitation, this study proposed a novel solution by designing a strong backup (SB) system to mitigate inter-story deformation concentration in “weak” stories. The proposed SB system consisting of truss members can be attached to the existing SC-CBF through pin connections, forming a system, termed strong backup SC-CBF (SC-CBF-SB), to promote a more uniform distribution of inter-story drifts along the height of the frame and mitigate the weak story behavior. A six-story chevron-braced frame is adopted to investigate the seismic performance of SC-CBF and SC-CBF-SB. Finite element models of SC-CBF and SC-CBF-SB are built. The mechanical characteristics and dynamic responses of the SC-CBF-SB are examined. To comprehensively evaluate the performance of both SC-CBF and SC-CBF-SB, static pushover analyses and nonlinear time-history analyses are conducted. Additionally, incremental dynamic analysis (IDA) is performed to evaluate the responses (particularly drift concentration) of both frame types subjected to increasing seismic intensity levels. Numerical results show that the maximum value of the drift concentration factor (DCF) is around 1.3 and 1.8 for SC-CBF-SB and SC-CBF, respectively, indicating that SC-CBF-SB can effectively mitigate inter-story drift concentration of SC-CBF. Meanwhile, the proposed SB system has a minimal negative impact on the favorable SC ability of the frame.
Keywords: Drift concentration factor
Inter-story drift
Seismic performance
Self-centering braced frame
Strong backup system
Publisher: Springer Dordrecht
Journal: Bulletin of earthquake engineering 
ISSN: 1570-761X
EISSN: 1573-1456
DOI: 10.1007/s10518-024-01997-8
Rights: © The Author(s) 2024
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
The following publication Huang, J., Zhu, S. Mitigating inter-story drift concentration in seismic-resistant self-centering braced frames by using strong backup systems. Bull Earthquake Eng (2024) is available at https://doi.org/10.1007/s10518-024-01997-8.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
s10518-024-01997-8.pdf2.21 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

12
Citations as of Oct 13, 2024

Downloads

4
Citations as of Oct 13, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.