Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/106394
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Mechanical Engineering | - |
dc.creator | Li, Y | - |
dc.creator | Wang, K | - |
dc.creator | Wang, Q | - |
dc.creator | Yang, J | - |
dc.creator | Zhou, P | - |
dc.creator | Su, Y | - |
dc.creator | Guo, S | - |
dc.creator | Su, Z | - |
dc.date.accessioned | 2024-05-09T00:53:12Z | - |
dc.date.available | 2024-05-09T00:53:12Z | - |
dc.identifier.issn | 1475-9217 | - |
dc.identifier.uri | http://hdl.handle.net/10397/106394 | - |
dc.language.iso | en | en_US |
dc.publisher | Sage Publications Ltd. | en_US |
dc.rights | This is the accepted version of the publication Li Y, Wang K, Wang Q, et al. Acousto-ultrasonics-based health monitoring for nano-engineered composites using a dispersive graphene-networked sensing system. Structural Health Monitoring. 2021;20(1):240-254. Copyright © 2020 The Author(s). DOI: 10.1177/1475921720929749. | en_US |
dc.subject | Acoustic emission | en_US |
dc.subject | Graphene-networked sensing system | en_US |
dc.subject | Guided ultrasonic waves | en_US |
dc.subject | Nano-engineered composites | en_US |
dc.subject | Structural health monitoring | en_US |
dc.title | Acousto-ultrasonics-based health monitoring for nano-engineered composites using a dispersive graphene-networked sensing system | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.identifier.spage | 240 | - |
dc.identifier.epage | 254 | - |
dc.identifier.volume | 20 | - |
dc.identifier.issue | 1 | - |
dc.identifier.doi | 10.1177/1475921720929749 | - |
dcterms.abstract | Sensing is a fundamental yet crucial part of a functional structural health monitoring system. Substantial research has been invested in developing new sensing techniques to enhance sensing efficiency and accuracy. Practical applications of structural health monitoring approaches to real engineering structures require strict criteria for the sensing system (e.g. weight, position, intrusion and endurance), which challenge existing sensing techniques. The boom in nanotechnology has offered promising solutions for the development of new sensing approaches. However, a bottleneck still exists when considering the density of sensors and surface-mounted modality of installation. In this study, graphene nanoparticles are dispersed into a glass fibre/epoxy composite to form a dispersive network sensing system. The piezoresistivity of the graphene-formed network changes locally as a result of the change of inter-nanoparticle distances which triggers the ‘tunnelling effect’ and drives the sensor to respond to propagating elastic waves. Due to the dense graphene network formed within the composite, only a small area is required, functioning as a single sensing element to capture ultrasonic waves. To validate such capability, passive acoustic emission tests and active guided ultrasonic wave tests are performed individually. The graphene-networked sensing system can precisely capture wave signals which contain effective features to identify impact spot or damage location. Integrating passive graphene-formed network and active lead zirconate titanate wafers can form a dense network, capable of fulfilling general structural health monitoring tasks. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Structural health monitoring, Jan. 2021, v. 20, no. 1, p. 240-254 | - |
dcterms.isPartOf | Structural health monitoring | - |
dcterms.issued | 2021-01 | - |
dc.identifier.scopus | 2-s2.0-85086578459 | - |
dc.identifier.eissn | 1741-3168 | - |
dc.description.validate | 202405 bcch | - |
dc.description.oa | Accepted Manuscript | en_US |
dc.identifier.FolderNumber | ME-0332 | en_US |
dc.description.fundingSource | RGC | en_US |
dc.description.fundingSource | Others | en_US |
dc.description.fundingText | National Natural Science Foundation of China | en_US |
dc.description.pubStatus | Published | en_US |
dc.identifier.OPUS | 30214208 | en_US |
dc.description.oaCategory | Green (AAM) | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Li_Acousto-Ultrasonics-Based_Health_Monitoring.pdf | Pre-Published version | 2.37 MB | Adobe PDF | View/Open |
Page views
7
Citations as of Jun 30, 2024
Downloads
4
Citations as of Jun 30, 2024
SCOPUSTM
Citations
8
Citations as of Jul 4, 2024
WEB OF SCIENCETM
Citations
6
Citations as of Jul 4, 2024
![](/image/google_scholar.jpg)
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.