Abstract: Purpose: To investigate whether OCT measurements can improve visual field (VF) trend analyses in glaucoma patients using the deeply regularized latent-space linear regression (DLLR) model.
Design: Retrospective cohort study.
Participants: Training and testing datasets included 7984 VF results from 998 eyes of 592 patients and 1184 VF results from 148 eyes of 84 patients with open-angle glaucoma, respectively. Each eye underwent a series of 8 VF tests with the Humphrey Field Analyzer OCT series obtained within the same observation period.
Methods: Using pointwise linear regression (PLR), the threshold values of a patient’s eighth VF results were predicted using values from shorter VF series (first to second VF tests [VF1–2], first to third VF tests, . . . , to first to seventh VF tests [VF1–7]), and the root mean square error (RMSE) was calculated. With DLLR, OCT measurements (macular retinal nerve fiber layer thickness, the thickness of macular ganglion cell layer and inner plexiform layer, and the thickness of the outer segment and retinal pigment epithelium) that were obtained within the period of shorter VF series were incorporated into the model to predict the eighth VF.
Main Outcome Measures: Prediction accuracy of VF trend analyses.
Results: The mean ± standard deviation RMSE resulting from PLR averaged 27.48 ± 16.14 dB for VF1–2 and 3.98 ± 2.25 dB for VF1–7. Significantly (P < 0.001) smaller RMSEs were obtained from DLLR: 4.57 ± 2.71 dB (VF1–2) and 3.65 ± 2.27 dB (VF1–7).
Conclusions: It is useful to include OCT measurements when predicting future VF progression in glaucoma patients, especially with short VF series.
Keywords: Deep learning
Glaucoma
OCT
Progression
Visual field
Publisher: Elsevier BV
Journal: Ophthalmology glaucoma 
ISSN: 2589-4234
EISSN: 2589-4196
DOI: 10.1016/j.ogla.2020.08.002
Rights: © 2020 by the American Academy of Ophthalmology
© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Xu, L., Asaoka, R., Murata, H., Kiwaki, T., Zheng, Y., Matsuura, M., ... & Yamanishi, K. (2021). Improving visual field trend analysis with OCT and deeply regularized latent-space linear regression. Ophthalmology Glaucoma, 4(1), 78-88 is available at https://doi.org/10.1016/j.ogla.2020.08.002.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Xu_Improving_Visual_Field.pdfPre-Published version849.69 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

20
Citations as of Jul 7, 2024

Downloads

7
Citations as of Jul 7, 2024

SCOPUSTM   
Citations

4
Citations as of Jul 4, 2024

WEB OF SCIENCETM
Citations

3
Citations as of Jul 4, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.