Title: Contactless respiration monitoring using ultrasound signal with off-the-shelf audio devices
Authors: Wang, T
Zhang, D
Wang, L
Zheng, Y 
Gu, T
Dorizzi, B
Zhou, X
Issue Date: Apr-2019
Source: IEEE internet of things journal, Apr. 2019, v. 6, no. 2, 8502803, p. 2959-2973
Abstract: Recent years have witnessed advances of Internet of Things technologies and their applications to enable contactless sensing and elderly care in smart homes. Continuous and real-time respiration monitoring is one of the important applications to promote assistive living for elders during sleep and attracted wide attention in both academia and industry. Most of the existing respiration monitoring systems require expensive and specialized devices to sense chest displacement. However, chest displacement is not a direct indicator of breathing and thus false detection may often occur. In this paper, we design and implement a real-time and contactless respiration monitoring system by directly sensing the exhaled airflow from breathing using ultrasound signals with off-the-shelf speaker and microphone. Exhaled airflow from breathing can be regarded as air turbulence, which scatters the sound wave and results in Doppler effect. Our system works as an acoustic radar which transmits sound wave and detects the Doppler effect caused by breathing airflow. We mathematically model the relationship between the Doppler frequency change and the direction of breathing airflow. Based on this model, we design a minimum description length-based algorithm to effectively capture the Doppler effect caused by exhaled airflow. We conduct extensive experiments with 25 participants (7 elders, 2 young kids, and 16 adults, including 11 females and 14 males) in four different rooms. The participants take four different sleep postures (lying on one's back, on right/left side, and on one's stomach) in different positions of the bed. Experiment results show that our system achieves a median error lower than 0.3 breaths/min (2%) for respiration monitoring and can accurately identify Apnea. The results also demonstrate that the system is robust to different respiration styles (shallow, normal, and deep), respiration rate variation, ambient noise, sensing distance variation (within 0.7 m), and transmitted signal frequency variation.
Keywords: Acoustic sensing
Contactless sensing
Doppler effect
Respiration detection
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE internet of things journal 
EISSN: 2327-4662
DOI: 10.1109/JIOT.2018.2877607
Rights: © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication T. Wang et al., "Contactless Respiration Monitoring Using Ultrasound Signal With Off-the-Shelf Audio Devices," in IEEE Internet of Things Journal, vol. 6, no. 2, pp. 2959-2973, April 2019 is available at https://doi.org/10.1109/JIOT.2018.2877607
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Zheng_Contactless_Respiration_Monitoring.pdfPre-Published version1.43 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

73
Last Week
0
Last month
Citations as of Sep 22, 2024

Downloads

229
Citations as of Sep 22, 2024

SCOPUSTM   
Citations

62
Citations as of Sep 26, 2024

WEB OF SCIENCETM
Citations

51
Citations as of Sep 26, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.