Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/93656
PIRA download icon_1.1View/Download Full Text
Title: Follow the curve : robotic ultrasound navigation with learning-based localization of spinous processes for scoliosis assessment
Authors: Victorova, M 
Lee, MKS 
Navarro-Alarcon, D 
Zheng, Y 
Issue Date: 2022
Source: IEEE access, 2022, v. 10, p. 40216-40229
Abstract: The scoliosis progression in adolescents requires close monitoring to timely take treatment measures. Ultrasound imaging is a radiation-free alternative in scoliosis assessment to X-ray, which is typically used in clinical practice. However, ultrasound images are prone to speckle noise, making it challenging for sonographers to detect bony features and follow the spinal curvature. This study introduces a novel robotic ultrasound approach for spinous process localization and automatic spinal curvature tracking for scoliosis assessment. The positions of the spinous processes are computed using a fully connected network with a deconvolutional head. A 5-fold cross-validation was performed on a dataset of ultrasound images from 25 human subjects with scoliosis. The resulting percentage of correct keypoints of the spinous process is 0.966 ± 0.027 with a mean distance error of 1.0 ± 0.99mm. We use this machine learning-based method to guide the motion of the robot-held ultrasound probe and to follow the spinal curvature while capturing ultrasound images. We present a new force-driven controller that automatically adjusts the pose and orientation of the probe relative to the skin surface, which ensures a good acoustic coupling between the probe and skin. We extended the network architecture to additionally perform classification of the spine into its regions, i.e., sacrum, lumbar, and thoracic, which are used to adjust the probe’s orientation to account for the varying curvature along the spine. After the autonomous scanning, the acquired data is used to reconstruct the coronal spinal image, where the deformity of the scoliosis spine can be assessed and measured. The proposed learning-based method for anatomical landmarks localization was compared to conventional methods based on phase symmetry and image intensity. The learning-based method proved to be more precise for spinous process localization while processing images at a faster rate, which is advantageous for real-time scoliosis scanning. To evaluate the performance of our robotic method, we conducted an experimental study with human scoliosis subjects where deviations of the spinous process from the image center can be compared to those appearing in a manual scan. Our results show that the robotic approach reduces the mean error of spinal curvature following for mild scoliosis from 4.6 ± 4.6mm (manual scanning) to 1.0 ± 0.8mm (robotic scanning); For moderate scoliosis from 4.3 ± 3.9mm (manual scanning) to 2.8 ± 1.8mm (robotic scanning). The angles of spinal deformity measured on spinal reconstruction images were similar for both methods, implying that they equally reflect human anatomy. The spinal region-specific moment-based probe orientation control showed to improve the scanning performance. An ablation study was performed to investigate the importance of each component of the proposed system.
Keywords: Computer vision for medical robotics
Medical robots and systems
Robotic manipulation
Scoliosis
Spinous process
Ultrasound navigation
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE access 
EISSN: 2169-3536
DOI: 10.1109/ACCESS.2022.3165936
Rights: This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
The following publication Victorova, M., Lee, M. K. S., Navarro-Alarcon, D., & Zheng, Y. (2022). Follow the Curve: Robotic Ultrasound Navigation With Learning-Based Localization of Spinous Processes for Scoliosis Assessment. IEEE Access, 10, 40216-40229 is available at https://doi.org/10.1109/ACCESS.2022.3165936
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Victorova_Follow_Curve_Robotic.pdf2.8 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

52
Last Week
1
Last month
Citations as of May 5, 2024

Downloads

29
Citations as of May 5, 2024

SCOPUSTM   
Citations

9
Citations as of Apr 26, 2024

WEB OF SCIENCETM
Citations

5
Citations as of May 2, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.