Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/87629
Title: | A robust calibration method for consumer grade RGB-D sensors for precise indoor reconstruction | Authors: | Darwish, W Li, WB Tang, SJ Wu, B Chen, W |
Issue Date: | 2019 | Source: | IEEE access, 2019, v. 7, p. 8824-8833 | Abstract: | RGB-D cameras, which can be attached to any mobile device and work under different operation platforms (e.g., iOS, Android, and Windows), have great potential for indoor 3D modeling and navigation due to their low cost and small size. The main problems of RGB-D cameras for such applications are their range limitations and deteriorated depth accuracy. For example, for a 7-m range, the distance error of structure sensor (one type of RGB-D camera) reaches nearly 0.5 m. We propose a new calibration procedure for RGB-D sensors to improve the depth accuracy. First, the baseline between RGB and IR cameras is calibrated using the direct linear transform method. The distortions of the RGB and IR cameras and the IR projector are then calibrated using the newly proposed two-lens distortion model. Finally, the remaining depth systematic errors are calibrated using an empirical model. Compared to existing calibration methods, the new calibration method considers distortions from both the IR camera and projector and significantly improves the accuracy of far-range depth measurements. The experimental results show that the proposed calibration method can precisely calibrate the full range of the RGB-D sensor, up to 7 m, with an overall depth accuracy of 1.9%, compared to the 5.5% accuracy of the manufacturer's depth estimation. To demonstrate the significance of calibration in indoor mapping, the 3D point cloud of a room (4.5 m x 3.5 m) is generated using the RGB-D SLAM system. The accuracy of the 3D model with the proposed calibration method is approximately 1.5 cm, compared to 7.0 cm using the manufacturer's calibration parameters. | Keywords: | Rgb-d Structured light Calibration RGB-D distortion Depth modeling |
Publisher: | Institute of Electrical and Electronics Engineers | Journal: | IEEE access | EISSN: | 2169-3536 | DOI: | 10.1109/ACCESS.2018.2890713 | Rights: | © 2019 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission.See http://www.ieee.org/publications_standards/publications/rights/index.html for more information. Posted with permission of publisher. The following publication W. Darwish, W. Li, S. Tang, B. Wu and W. Chen, "A Robust Calibration Method for Consumer Grade RGB-D Sensors for Precise Indoor Reconstruction," in IEEE Access, vol. 7, pp. 8824-8833, 2019 is available at https://dx.doi.org/10.1109/ACCESS.2018.2890713 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Darwish_Consumer_Grade_RGB-D.pdf | 1.78 MB | Adobe PDF | View/Open |
Page views
64
Last Week
0
0
Last month
Citations as of May 5, 2024
Downloads
93
Citations as of May 5, 2024
SCOPUSTM
Citations
11
Citations as of Apr 26, 2024
WEB OF SCIENCETM
Citations
8
Citations as of May 2, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.