Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/64430
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Electrical Engineering-
dc.creatorCai, GWen_US
dc.creatorMu, Gen_US
dc.creatorCheng, HZen_US
dc.creatorChan, KWen_US
dc.date.accessioned2017-02-22T07:34:36Z-
dc.date.available2017-02-22T07:34:36Z-
dc.identifier.issn1004-9649en_US
dc.identifier.urihttp://hdl.handle.net/10397/64430-
dc.language.isozhen_US
dc.publisher水利電力出版社en_US
dc.rights© 2002 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。en_US
dc.rights© 2002 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research purposes.en_US
dc.subjectDynamic security assessmenten_US
dc.subjectCritical machineen_US
dc.subjectCritical cutseten_US
dc.subjectLine potential energyen_US
dc.titleApproach to identify the critical cluster of machines based on line transient potential energy and voltageen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage40en_US
dc.identifier.epage44en_US
dc.identifier.volume35en_US
dc.identifier.issue5en_US
dcterms.abstractReliability and computational simplicity in identification of cluster of critical machines are of primary importance in application of direct and hybrid transient stability assessment methods such as TEF,EEAC and hybrid TEF and hybrid EEAC.In the paper,a new approach is proposed for classifying machines into critical cluster and remaining cluster by identifying critical cutset(the weakest cutset)with quantitative assessment index,which is built on the basis of investigation in the feature of transient potential energy over network injected into the post-fault system and the change of bus voltage after removal of the disturbance.The algorithm only requires variables of line power,bus phase angle and bus voltage along the post-fault trajectory instead of generator dynamic variables.The case studies on the10machines39buses New England system are given to show the validation of this method.-
dcterms.accessRightsopen accessen_US
dcterms.alternative基于支路暫態勢能和兩端電壓識別臨界機群的新方法en_US
dcterms.bibliographicCitation中國電力 (Electric power), 2002, v. 35, no. 5, p. 40-44en_US
dcterms.isPartOf中國電力 (Electric power)en_US
dcterms.issued2002-
dc.identifier.rosgroupidr10012-
dc.description.ros2001-2002 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Cai_Approach_Identify_Critical.pdf670.53 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

53
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

21
Citations as of Apr 21, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.