Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/102844
PIRA download icon_1.1View/Download Full Text
Title: Study on the effects of runner geometries on the performance of inline cross-flow turbine used in water pipelines
Authors: Du, J 
Shen, Z 
Yang, H 
Issue Date: Aug-2020
Source: Sustainable energy technologies and assessments, Aug. 2020, v. 40, 100762
Abstract: To supply continuous and reliable power to the water monitoring systems and motorized control valves in urban water supply networks, the inline cross-flow turbine has been developed. This study aims to investigate the effects of different runner geometries on the performance of inline cross-flow turbines and to determine the optimal runner geometrical parameters. In this paper, a theoretical analysis of the working mechanism of a cross-flow runner is first performed to study the impacts of the runner geometry on turbine performance. Thereafter, several turbine models with different runner geometries are built and simulated to analyse the output power, water head reduction and torque generation at each runner stage. The results indicate that a good match between the flow inlet angle and blade outer angle notably enhances the turbine performance. Based on the results, the recommended optimal blade outer angle in this research is 30°. In addition, the results also show that the runner diameter ratio has a major impact on torque generation at the runner first stage. A lower runner diameter ratio leads to a higher output power, but the water head reduction is also higher. Based on the results, the suggested runner diameter ratio is 0.68. A numerical study on the number of blades indicates that when the number of blades increases from 20 to 24, the turbine output power considerably rises, and the maximum output power reaches 2285 W. However, if the blade number is further increased, the variation in output power is very slight. Thus, the proposed optimal blade number is 24. Based on the research results, the maximum turbine efficiency can reach 50.9% after runner optimization.
Keywords: Blade outer angle
Inline cross-flow turbine
Micro hydropower generation
Runner diameter ratio
Water pipeline
Publisher: Elsevier BV
Journal: Sustainable energy technologies and assessments 
ISSN: 2213-1388
EISSN: 2213-1396
DOI: 10.1016/j.seta.2020.100762
Rights: © 2020 Elsevier Ltd. All rights reserved.
© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Du, J., Shen, Z., & Yang, H. (2020). Study on the effects of runner geometries on the performance of inline cross-flow turbine used in water pipelines. Sustainable Energy Technologies and Assessments, 40, 100762 is available at https://doi.org/10.1016/j.seta.2020.100762.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Du_Study_Effects_Runner.pdfPre-Published version2.32 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

94
Last Week
3
Last month
Citations as of Nov 9, 2025

Downloads

85
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

19
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

13
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.