Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/101246
PIRA download icon_1.1View/Download Full Text
Title: Numerical analysis and punching shear fracture based design of longitudinal plate to concrete-filled CHS connections
Authors: Xu, F 
Chen, J
Chan, TM 
Issue Date: 15-Dec-2017
Source: Construction and building materials, 15 Dec. 2017, v. 156, p. 91-106
Abstract: The mechanical behaviour of longitudinal plate-to-concrete-filled circular hollow section (CHS) connections under axial tension, eccentric tension and in-plane bending is extensively studied by the experimentally validated finite element analysis (FEA) in this paper. A total of 336 connections with a wide range of parameters on geometrical configurations, material properties and load positions was conducted to investigate (a) the general applicability of the experimental conclusion for the governing limit state, (b) the shear stress profile on the failure face and (c) the design equations based on fracture analytical models under various loading conditions. FEA extended the validity of experimental conclusion that the only governing limit state was punching shear failure instead of the deformation limit of 3% chord diameter (D). With an aim of proposing design equations based on ductile fracture mechanics, the stress distributions on the fracture failure face and the inner concrete were investigated by the parametric study, and then were adopted in the analytical models. Finally, design equations based on semi-theoretical models for the ultimate strength of longitudinal plate-to-concrete-filled CHS connections under three investigated loads were proposed. It is found the connection-capacity predictions agreed with both test and FEA results well.
Keywords: Concrete-filled steel tubes
Design
Ductile fracture
Finite element analysis
Longitudinal plate connections
Punching shear
Publisher: Elsevier
Journal: Construction and building materials 
ISSN: 0950-0618
DOI: 10.1016/j.conbuildmat.2017.08.098
Rights: © 2017 Elsevier Ltd. All rights reserved.
© 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Xu, F., Chen, J., & Chan, T. M. (2017). Numerical analysis and punching shear fracture based design of longitudinal plate to concrete-filled CHS connections. Construction and Building Materials, 156, 91-106 is available at https://doi.org/10.1016/j.conbuildmat.2017.08.098.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Chan_Numerical_Analysis_Punching.pdfPre-Published version2.69 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

88
Last Week
1
Last month
Citations as of Nov 9, 2025

Downloads

89
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

22
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

22
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.