Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/99547
PIRA download icon_1.1View/Download Full Text
Title: Cross-infection risk assessment in dental clinic : numerical investigation of emitted droplets during different atomization procedures
Authors: Li, X 
Mak, CM 
Ai, Z 
Ma, KW 
Wong, HM
Issue Date: 15-Sep-2023
Source: Journal of building engineering, 15 Sept. 2023, v. 75, 106961
Abstract: Cross-infection risk induced by the emitted droplets and bioaerosols during dental procedures has challenged service providers and patients alike. The present study aims to investigate the transmission mechanism of emitted droplets during the dental atomization procedures: vibration ultrasonic scaling (vUS) and rotation high-speed drilling (rHSD) and propose the risk assessment. Computational fluid dynamics (CFD) simulation was performed, and the experimentally recorded droplet velocity and diameter distribution during the atomization procedures were defined as initial boundary conditions. The droplet transmission in the dental clinic was analyzed from the final fate (deposition, suspension, and escape) and fallow time (FT) of emitted droplets. The results revealed that the diameter threshold for the droplet deposition and suspension was 60μm, and the fraction of deposited droplets would be stable at 79.5% for rHSD and 85% for vUS. The primary contamination distance was generally within 0.28 m and 0.4 m from the treatment position for the atomization procedures of rHSD and vUS, respectively. An increment of about 2% in the fraction of escaped droplets was noted when conducting the rHSD. The median of estimated FT for the atomization procedure of rHSD, 34 min, was longer than that of vUS, 30.6 min. In general, cross-infection risk during rHSD can be regarded as “higher” than vUS. The contribution of the present study can serve as guidance to decrease the cross-infection risk in dental clinics.
Keywords: Computational fluid dynamics (CFD)
Cross-infection risk
Dental atomization procedure
Dental clinic
Droplet
Publisher: Elsevier
Journal: Journal of building engineering 
EISSN: 2352-7102
DOI: 10.1016/j.jobe.2023.106961
Rights: © 2023 Elsevier Ltd. All rights reserved.
© 2023. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Xiujie Li, Cheuk Ming Mak, Zhengtao Ai, Kuen Wai Ma, Hai Ming Wong, “Cross-infection risk assessment in dental clinic: numerical investigation of emitted droplets during different atomization procedures”, (2023), 106961, 75, Journal of Building Engineering is available at https://doi.org/10.1016/j.jobe.2023.106961.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Li_Cross_infection_Risk_Assessment.pdfPre-Published version2.6 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

109
Last Week
20
Last month
Citations as of Aug 17, 2025

SCOPUSTM   
Citations

19
Citations as of Aug 29, 2025

WEB OF SCIENCETM
Citations

17
Citations as of Aug 28, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.