Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/99528
PIRA download icon_1.1View/Download Full Text
Title: Numerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service
Authors: Li, X 
Mak, CM 
Ai, Z 
Ma, KW 
Wong, HM
Issue Date: Apr-2023
Source: Physics of fluids, Apr. 2023, v. 35, no. 4, 43332
Abstract: Dental services are yet to return to a semblance of normality owing to the fear and uncertainty associated with the possible airborne transmission of diseases. The present study aims to investigate the impacts of environmental conditions [changes in ventilation location, ventilation rate, and relative humidity (RH)] and variations in dental patient's breathing rate on droplet transmission during dental service. Computational fluid dynamics simulation was performed based on our previous experimental study during ultrasonic scaling. The impacts of different factors were numerically analyzed by the final fate and proportion of emitted droplets in the dental surgery environment. The results revealed that about 85% of droplets deposited near the dental treatment region, where the patient's torso, face, and floor (dental chair) accounted for around 63%, 11%, and 8.5%, respectively. The change in the ventilation location had a small impact on the deposition of larger droplets ( > 60 μ m ), and a spatial region with high droplet mass concentration would be presented near the dental professional. The change in the ventilation rate from 5 to 8 ACH led to a 1.5% increment in the fraction of escaped droplets. 50% RH in dental environments was recommended to prevent droplets' fast evaporation and potential mold. Variations in the patient's breathing rate had little effect on the final fate and proportion of emitted droplets. Overall, environmental factors are suggested to maintain 50% RH and larger ACH in dental surgery environments. The findings can give policymakers insights into the role of environmental factors on infection control.
Publisher: American Institute of Physics
Journal: Physics of fluids 
ISSN: 1070-6631
EISSN: 1089-7666
DOI: 10.1063/5.0144647
Rights: © 2023 Author(s). Published under an exclusive license by AIP Publishing.
This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Li, X., Mak, C. M., Ai, Z., Ma, K. W., & Wong, H. M. (2023). Numerical investigation of the impacts of environmental conditions and breathing rate on droplet transmission during dental service. Physics of Fluids, 35(4), 043332 and may be found at https://doi.org/10.1063/5.0144647.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
043332_1_5.0144647.pdf6.04 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

109
Last Week
3
Last month
Citations as of Nov 9, 2025

Downloads

78
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

18
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

17
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.