Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/99090
| Title: | Indirect evaporative cooling maps of China : optimal and quick performance identification based on a data-driven model | Authors: | Shi, W Ma, X Gu, Y Min, Y Yang, H |
Issue Date: | 15-Sep-2022 | Source: | Energy conversion and management, 15 Sept 2022, v. 268, 116047 | Abstract: | The data-driven models of various air conditioning (AC) systems have been developed because of the wider application of machine learning in the engineering field. Indirect evaporative cooler (IEC), known as one of the effective and environment-friendly AC devices, achieves the cooling purpose without using any types of mechanical compressors or chemical refrigerants. Recent studies on various IECs have been carried out in full swing with a large amount of valuable data produced. However, the data-driven model of the cross-flow IEC for sensible and total cooling is yet to be developed. In addition, by extracting the indoor cold exhaust air into the secondary air channel, the application range of an IEC can be extended, but so far the performance of IEC used in different regions has been rarely evaluated. In this study, an IEC model was established based on the artificial neural network (ANN), which was validated with on-site measurement results from a real engineering project. Combining the selected geometric size of IEC and various outdoor weather conditions into the IEC-ANN model, a case study was conducted to present the annual and seasonal IEC performance maps of China, and the optimal application regions could be determined. Results show that south China, east China, and middle China are more suitable to employ IEC for air treatment and energy saving. In south China, the greatest average temperature drop caused by the IEC is 4.52 ℃. The maximum cooling capacity can reach 5.74 kW, and it accounts for 30.1 % of the total cooling load. In the typical office building, the seasonal energy saving of the IEC with the given size is up to 3.64 kWh/m2, and the annual energy saving can reach 6.02 kWh/m2. In addition, the inference time of this IEC-ANN model was significantly shorter compared with a numerical model. Based on the quick prediction speed, the model can improve the working efficiency in the design stage of the engineering and may provide a swift response to guide the system operation. | Keywords: | Air conditioning Data-driven model Indirect evaporative cooling Cooling map Optimal and quick identification |
Publisher: | Elsevier Ltd | Journal: | Energy conversion and management | ISSN: | 0196-8904 | EISSN: | 1879-2227 | DOI: | 10.1016/j.enconman.2022.116047 | Rights: | © 2022 Elsevier Ltd. All rights reserved. © 2022. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/. The following publication Shi, W., Ma, X., Gu, Y., Min, Y., & Yang, H. (2022). Indirect evaporative cooling maps of China: Optimal and quick performance identification based on a data-driven model. Energy Conversion and Management, 268, 116047 is available at https://dx.doi.org/10.1016/j.enconman.2022.116047. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Shi_Indirect_Evaporative_Cooling.pdf | Pre-Published version | 2.41 MB | Adobe PDF | View/Open |
Page views
93
Citations as of Nov 10, 2025
Downloads
66
Citations as of Nov 10, 2025
SCOPUSTM
Citations
16
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
12
Citations as of Sep 26, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



