Title: FRF-based transient wave analysis for the viscoelastic parameters identification and leak detection in water-filled plastic pipes
Authors: Pan, B 
Duan, HF 
Meniconi, S
Brunone, B
Issue Date: 1-Jan-2021
Source: Mechanical systems and signal processing, 1 Jan. 2021, v. 146, 107056
Abstract: Plastic/viscoelastic pipes, such as polyvinyl chloride (PVC), polyethylene (PE) and high-density polyethylene (HDPE), have been increasingly used in water piping systems, which has stimulated the study of viscoelastic hydrodynamics in these pipe systems. An in-depth understanding of the pipe-wall viscoelasticity features is beneficial and necessary to the effective application and management of plastic pipes such as leak detection in urban water supply systems. This paper presents a frequency response function (FRF)-based transient wave analysis method (TWAM) for the identification of viscoelastic pipe properties as well as the detection of leaks in water filled plastic pipes. To this end, an analytical FRF expression is firstly derived for the interaction of transients with pipe-wall elasticity and leaks in plastic pipes, which is thereafter used for the identification of viscoelastic parameters and potential leaks in plastic pipes. Laboratory experiments are performed to validate the proposed FRF-based TWAM and thereby examining the effective range of injected wave bandwidth for accurate leak detection with existence of pipe-wall viscoelasticity. The validated method is further analyzed through extensive numerical applications to systematically examine the influences of different system and flow conditions. Application results confirm the feasibility and accuracy of the developed FRF-based TWAM method for the identification of viscoelastic parameters as well as the detection of plastic pipe leaks. The results also indicate that the proposed method in this study is more accurate to locate leaks than to size leaks in plastic pipes, which requires more attention to the future applications.
Keywords: Bandwidth
Frequency response function (FRF)
Leak detection
Plastic pipes
Transient wave analysis
Viscoelasticity
Publisher: Academic Press
Journal: Mechanical systems and signal processing 
ISSN: 0888-3270
EISSN: 1096-1216
DOI: 10.1016/j.ymssp.2020.107056
Rights: © 2020 Elsevier Ltd. All rights reserved.
© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Pan, B., Duan, H. F., Meniconi, S., & Brunone, B. (2021). FRF-based transient wave analysis for the viscoelastic parameters identification and leak detection in water-filled plastic pipes. Mechanical Systems and Signal Processing, 146, 107056 is available at https://doi.org/10.1016/j.ymssp.2020.107056.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Pan_FRF-Based_Transient_Wave.pdfPre-Published version1.58 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

102
Last Week
2
Last month
Citations as of Nov 9, 2025

Downloads

148
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

56
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

50
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.