Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/97970
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Civil and Environmental Engineeringen_US
dc.creatorZhang, Yen_US
dc.creatorDuan, HFen_US
dc.creatorKeramat, Aen_US
dc.creatorChe, TCen_US
dc.date.accessioned2023-04-06T07:17:34Z-
dc.date.available2023-04-06T07:17:34Z-
dc.identifier.issn0888-3270en_US
dc.identifier.urihttp://hdl.handle.net/10397/97970-
dc.language.isoenen_US
dc.publisherAcademic Pressen_US
dc.rights© 2021 Elsevier Ltd. All rights reserved.en_US
dc.rights© 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.en_US
dc.rightsThe following publication Zhang, Y., Duan, H.-F., Keramat, A., & Che, T.-C. (2022). On the leak-induced transient wave reflection and dominance analysis in water pipelines. Mechanical Systems and Signal Processing, 167, 108512 is available at https://dx.doi.org/10.1016/j.ymssp.2021.108512.en_US
dc.subjectDominance analysisen_US
dc.subjectLeak detectionen_US
dc.subjectPipeline health monitoringen_US
dc.subjectTransient reflection method (TRM)en_US
dc.subjectWave reflectionen_US
dc.subjectWave signal processingen_US
dc.titleOn the leak-induced transient wave reflection and dominance analysis in water pipelinesen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume167en_US
dc.identifier.issuept. Aen_US
dc.identifier.doi10.1016/j.ymssp.2021.108512en_US
dcterms.abstractThe leak-induced reflection information forms the basis of developing and applying transient-based leak detection methods in water-filled pipelines. The transient reflection method (TRM) has been widely incorporated in various leakage problems, and affecting parameters in the process are closely investigated in specific cases. However, the TRM literature lacks a global assessment of the relative importance of each parameter for a general inference on the contribution of each independent variable to the desired reflection criterion, which assists in leakage management. Besides, in the majority of previous studies, the leak-induced reflection wave at the measurement point is approximated by that at the leaky point, i.e., the propagation behavior and process of the reflected wave from the potential leak location to measurement point is ignored, leading to inaccuracy in sizing potential leaks by the TRM. To resolve these issues, this study firstly derives the leak-induced reflection coefficient at the measurement point by incorporating the additional damping effect of the reflection wave propagation process along the pipeline, which is then fully validated by MOC-based numerical and experimental laboratory applications. To further understand the contribution of different factors in the derived reflection coefficient, a systematic analysis is conducted based on dimensional analysis and extensive numerical simulations. The obtained results are characterized by the dominance analysis so as to explore the importance ranking of different dimensionless factors to the leak-induced reflection coefficient in the pipeline system. The analysis results indicate that, amongst all the dimensionless parameters, the leak factor provides the largest influence and contribution to the wave reflection coefficient (with about 40% contribution), followed by the transient intensity (23%) and initial system and flow conditions (20%), and lastly the measurement distance from leak location (17%). The finding of this study is helpful in leakage management as it aims to understand and explain the applicability and effectiveness of the TRM under different conditions.en_US
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationMechanical systems and signal processing, 15 Mar. 2022, v. 167, 108512en_US
dcterms.isPartOfMechanical systems and signal processingen_US
dcterms.issued2022-03-15-
dc.identifier.scopus2-s2.0-85117079815-
dc.identifier.eissn1096-1216en_US
dc.identifier.artn108512en_US
dc.description.validate202303 bcfcen_US
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumberCEE-0003-
dc.description.fundingSourceRGCen_US
dc.description.pubStatusPublisheden_US
dc.identifier.OPUS57194253-
dc.description.oaCategoryGreen (AAM)en_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Zhang_Leak-Induced_Transient_Wave.pdfPre-Published version7.03 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

127
Last Week
4
Last month
Citations as of Nov 30, 2025

Downloads

218
Citations as of Nov 30, 2025

SCOPUSTM   
Citations

15
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

13
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.