Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/97970
| DC Field | Value | Language |
|---|---|---|
| dc.contributor | Department of Civil and Environmental Engineering | en_US |
| dc.creator | Zhang, Y | en_US |
| dc.creator | Duan, HF | en_US |
| dc.creator | Keramat, A | en_US |
| dc.creator | Che, TC | en_US |
| dc.date.accessioned | 2023-04-06T07:17:34Z | - |
| dc.date.available | 2023-04-06T07:17:34Z | - |
| dc.identifier.issn | 0888-3270 | en_US |
| dc.identifier.uri | http://hdl.handle.net/10397/97970 | - |
| dc.language.iso | en | en_US |
| dc.publisher | Academic Press | en_US |
| dc.rights | © 2021 Elsevier Ltd. All rights reserved. | en_US |
| dc.rights | © 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/. | en_US |
| dc.rights | The following publication Zhang, Y., Duan, H.-F., Keramat, A., & Che, T.-C. (2022). On the leak-induced transient wave reflection and dominance analysis in water pipelines. Mechanical Systems and Signal Processing, 167, 108512 is available at https://dx.doi.org/10.1016/j.ymssp.2021.108512. | en_US |
| dc.subject | Dominance analysis | en_US |
| dc.subject | Leak detection | en_US |
| dc.subject | Pipeline health monitoring | en_US |
| dc.subject | Transient reflection method (TRM) | en_US |
| dc.subject | Wave reflection | en_US |
| dc.subject | Wave signal processing | en_US |
| dc.title | On the leak-induced transient wave reflection and dominance analysis in water pipelines | en_US |
| dc.type | Journal/Magazine Article | en_US |
| dc.identifier.volume | 167 | en_US |
| dc.identifier.issue | pt. A | en_US |
| dc.identifier.doi | 10.1016/j.ymssp.2021.108512 | en_US |
| dcterms.abstract | The leak-induced reflection information forms the basis of developing and applying transient-based leak detection methods in water-filled pipelines. The transient reflection method (TRM) has been widely incorporated in various leakage problems, and affecting parameters in the process are closely investigated in specific cases. However, the TRM literature lacks a global assessment of the relative importance of each parameter for a general inference on the contribution of each independent variable to the desired reflection criterion, which assists in leakage management. Besides, in the majority of previous studies, the leak-induced reflection wave at the measurement point is approximated by that at the leaky point, i.e., the propagation behavior and process of the reflected wave from the potential leak location to measurement point is ignored, leading to inaccuracy in sizing potential leaks by the TRM. To resolve these issues, this study firstly derives the leak-induced reflection coefficient at the measurement point by incorporating the additional damping effect of the reflection wave propagation process along the pipeline, which is then fully validated by MOC-based numerical and experimental laboratory applications. To further understand the contribution of different factors in the derived reflection coefficient, a systematic analysis is conducted based on dimensional analysis and extensive numerical simulations. The obtained results are characterized by the dominance analysis so as to explore the importance ranking of different dimensionless factors to the leak-induced reflection coefficient in the pipeline system. The analysis results indicate that, amongst all the dimensionless parameters, the leak factor provides the largest influence and contribution to the wave reflection coefficient (with about 40% contribution), followed by the transient intensity (23%) and initial system and flow conditions (20%), and lastly the measurement distance from leak location (17%). The finding of this study is helpful in leakage management as it aims to understand and explain the applicability and effectiveness of the TRM under different conditions. | en_US |
| dcterms.accessRights | open access | en_US |
| dcterms.bibliographicCitation | Mechanical systems and signal processing, 15 Mar. 2022, v. 167, 108512 | en_US |
| dcterms.isPartOf | Mechanical systems and signal processing | en_US |
| dcterms.issued | 2022-03-15 | - |
| dc.identifier.scopus | 2-s2.0-85117079815 | - |
| dc.identifier.eissn | 1096-1216 | en_US |
| dc.identifier.artn | 108512 | en_US |
| dc.description.validate | 202303 bcfc | en_US |
| dc.description.oa | Accepted Manuscript | en_US |
| dc.identifier.FolderNumber | CEE-0003 | - |
| dc.description.fundingSource | RGC | en_US |
| dc.description.pubStatus | Published | en_US |
| dc.identifier.OPUS | 57194253 | - |
| dc.description.oaCategory | Green (AAM) | en_US |
| Appears in Collections: | Journal/Magazine Article | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Zhang_Leak-Induced_Transient_Wave.pdf | Pre-Published version | 7.03 MB | Adobe PDF | View/Open |
Page views
127
Last Week
4
4
Last month
Citations as of Nov 30, 2025
Downloads
218
Citations as of Nov 30, 2025
SCOPUSTM
Citations
15
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
13
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.