Title: Comparison between the Instant Vision Assessment Device (IVAD) and the Focometer in determining refractive error
Authors: Tanabe, T
Li, HY 
Cheng, D 
Woo, GC 
Issue Date: Dec-2022
Source: Optometry & visual performance, Dec. 2022, v. 10, no. 4, p. 199-203
Abstract: Background: Uncorrected refractive error is a common cause of preventable blindness. In developing countries, eye care professionals and refraction tools are in scarce supply to meet the great demand for correcting refractive error. This study aims to compare the Focometer and the Instant Vision Assessment Device (IVAD) in obtaining subjective refractions.
Methods: Self-refractions were performed with the Focometer and the IVAD, respectively, on the right eye of 27 subjects. The range of age was from 23 to 51 years, and the mean age was 37.4±7.8 years. Subjects were in a rehabilitation center in Osaka, Japan. The spherical equivalent refraction findings obtained with both instruments were compared. Paired t-test, regression analysis, and Bland-Altman plot were used for statistical analysis.
Results: The mean spherical equivalent refraction and the standard error measured by the IVAD in the right eye was -2.00±0.46 D. With the Focometer, these were -1.89±0.47 D. The difference in the measurement and the standard error between the IVAD and the Focometer was -0.12±0.16 D, which was not statistically significant (p = 0.46, t = 0.75). The results obtained by the 2 instruments were highly correlated (R2 = 0.89; p = 0.00), and there was no systemic measurement difference between the two instruments.
Conclusions: Refractive error findings obtained with the Focometer and the IVAD are comparable to each other. Both instruments are valid and useful tools for determining spherical equivalent refractive error.
Keywords: Blindness
Focometer
Instant Vision Assessment Device
Refractive error
Publisher: Optometric Extension Program Foundation
Journal: Optometry & visual performance 
ISSN: 2325-3487
EISSN: 2325-3479
Rights: Posted with permission of the publisher.
The following publication Tanabe T, Li HY, Cheng D, Woo GC. Comparison between the Instant Vision Assessment Device (IVAD) and the Focometer in determining refractive error. Optom Vis Perf 2022;10(4):199-203 is available at https://www.ovpjournal.org/ovp---volume-10-issue-4.html.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Web-OVP10-4-Tanabe.pdf186.44 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

99
Citations as of Apr 14, 2025

Downloads

35
Citations as of Apr 14, 2025

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.