Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/96904
PIRA download icon_1.1View/Download Full Text
Title: Investigations into the local buckling and post-buckling behaviour of fixed-ended hybrid I-section stub columns with slender web
Authors: Chen, S 
Liu, JZ
Chan, TM 
Issue Date: Mar-2023
Source: Thin-walled structures, Mar. 2023, v. 184, 110174
Abstract: It has been known that thin plate can carry loads considerably more than the buckling loads. This phenomenon is defined as the post-buckling behaviour, which is affected by material properties, geometric dimensions and boundary conditions of the plate. Hybrid I-section is a design concept where flanges are made of high strength steel and web is made of lower steel grade. In order to investigate the effect of slender web on the local buckling and post buckling of hybrid I-section under pure compression, experimental studies of twelve fixed-ended I-section stub columns with slender web were conducted. Tensile coupon tests and initial local geometric imperfection measurement were carried out before stub column tests. Experimental and theoretical methods for determining the critical local buckling load of plate elements were discussed, followed by a post-test finite element analysis to investigate the effects of stub column length and sectional steel combination on the buckling behaviour. Based on the experimental and numerical results, it was observed that for specimens which web plate failed by elastic local buckling, the ultimate test loads are affected by the web strength grade, indicating that the unbuckled portion of slender web plate still provides the post-buckling strength for I-section stub columns even after yielding. By comparing the existing design methods with the numerical ultimate loads, it was found that the Eurocode 3 gives the less scattered predictions than the North American code, Australian code and Chinese code, as well as the existing direct strength method and continuous strength method.
Keywords: Local buckling
Post buckling
Hybrid I-section
Slender web
Stub column
Publisher: Pergamon Press
Journal: Thin-walled structures 
ISSN: 0263-8231
EISSN: 1879-3223
DOI: 10.1016/j.tws.2022.110174
Rights: © 2022 Elsevier Ltd. All rights reserved.
© 2022. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Chen, S., Liu, L., & Chan, T. M. (2023). Investigations into the local buckling and post-buckling behaviour of fixed-ended hybrid I-section stub columns with slender web. Thin-Walled Structures, 184, 110174 is available at https://doi.org/10.1016/j.tws.2022.110174.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Chen_Investigations_Local_Buckling.pdfPre-Published version2.49 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

67
Citations as of Apr 14, 2025

Downloads

1
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

4
Citations as of Jun 21, 2024

WEB OF SCIENCETM
Citations

10
Citations as of Apr 3, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.