| Title: | Performance evaluation of a double-pipe heat exchanger fitted with self-rotating twisted tapes | Authors: | Zhang, S Lu, L Dong, C Cha, SH |
Issue Date: | 25-Jul-2019 | Source: | Applied thermal engineering, 25 July 2019, v. 158, 113770 | Abstract: | This study presents heat transfer and frication factor characteristics of heat exchanger tube with self-rotating twisted tapes (SRTTs). A comparison of SRTTs and stationary twisted tapes (STTs) as well as an examination of the effects of SRTTs with different twist ratios (Y = 2.2, 3, 4, and 6) on the thermal characteristics were experimentally investigated under turbulence flows (12000 < Re < 45000). The experimental results showed that SRTTs under rotating conditions could enhance the thermal performance of heat exchanger as compared with STTs. The twist ratios were found to have less effect on the initial stages of the rotating behavior, and the SRTTs with lower twisted ratios rotated faster under the same operating conditions. In addition, it was observed that the Nusselt number, pressure drop, and thermal performance factor increased with decreasing twist ratios. The maximum thermal performance factors of 1.03, 0.9444, 0.924, and 0.898 could be achieved at the start of rotating behavior for Y = 2.2, 3, 4, and 6, respectively. Finally, some correlations of the Nusselt number and frication factor were established within ± 10% deviation of the experimental data. | Keywords: | Frication factor Heat transfer enhancement Self-rotating twisted tapes Thermal performance factor and Nusselt number |
Publisher: | Pergamon Press | Journal: | Applied thermal engineering | ISSN: | 1359-4311 | EISSN: | 1873-5606 | DOI: | 10.1016/j.applthermaleng.2019.113770 | Rights: | © 2019 Elsevier Ltd. All rights reserved. © 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/ The following publication Zhang, S., Lu, L., Dong, C., & Cha, S. H. (2019). Performance evaluation of a double-pipe heat exchanger fitted with self-rotating twisted tapes. Applied Thermal Engineering, 158, 113770 is available at https://doi.org/10.1016/j.applthermaleng.2019.113770. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Performance_Evaluation_Double-pipe.pdf | Pre-Published version | 1.43 MB | Adobe PDF | View/Open |
Page views
113
Last Week
0
0
Last month
Citations as of Dec 21, 2025
Downloads
154
Citations as of Dec 21, 2025
SCOPUSTM
Citations
56
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
50
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.