Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/95182
PIRA download icon_1.1View/Download Full Text
Title: Investigation on the regeneration performance of liquid desiccant by adding surfactant PVP-K30
Authors: Wen, T 
Lu, L 
Dong, C 
Luo, Y
Issue Date: Aug-2018
Source: International journal of heat and mass transfer, Aug. 2018, v. 123, p. 445-454
Abstract: The liquid desiccant cooling system (LDCS) is a promising alternative for the conventional vapor compression system due to its high energy efficiency. To enhance the mass transfer between the regeneration air and liquid desiccant in the regenerator, the paper firstly introduced a kind of surfactant called polyvinyl pyrrolidone (PVP-K30) which was added into the LiCl solution for better desiccant regeneration performance. The falling film characteristics and regeneration performance were investigated and compared with and without surfactant. The results indicated that the contact angle of desiccant solution on plate decreased from 58.5° to 28.0° by adding surfactant with 0.4% of concentration. The average wetting area increased from 0.174 m2 to 0.209 m2 with a relative increment of 20.1% with the addition of surfactant. Correspondingly, the film thickness had a reduction of 0.103 mm from 0.696 mm to 0.593 mm averagely. The regeneration rate had an average enhancement of 26.3% under the same working conditions, resulting from the decrement of solution contact angle with the addition of the surfactant. Finally, correlations to predict the mass transfer coefficient were proposed with and without surfactant and the mean absolute relative deviation between the results of correlations and the experiments were kept within 8%. The results and findings of present paper could be applied to guide the design of compact regenerator for higher regeneration performance.
Keywords: Correlation
Falling film
Mass transfer enhancement
Regeneration
Surfactant
Publisher: Pergamon Press
Journal: International journal of heat and mass transfer 
ISSN: 0017-9310
EISSN: 1879-2189
DOI: 10.1016/j.ijheatmasstransfer.2018.03.005
Rights: © 2018 Elsevier Ltd. All rights reserved.
© 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Wen, T., Lu, L., Dong, C., & Luo, Y. (2018). Investigation on the regeneration performance of liquid desiccant by adding surfactant PVP-K30. International Journal of Heat and Mass Transfer, 123, 445-454 is available at https://doi.org/10.1016/j.ijheatmasstransfer.2018.03.005.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Investigation_Regeneration_Performance.pdfPre-Published version1.27 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

126
Last Week
0
Last month
Citations as of Nov 9, 2025

Downloads

127
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

48
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

44
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.