Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/94821
PIRA download icon_1.1View/Download Full Text
Title: Application of a manufacturer’s guideline and an IDDSI-driven guideline to thickening of some non-water beverages : a rheological study
Authors: Kwong, E 
Tse, SK 
Issue Date: Apr-2021
Source: Dysphagia, Apr. 2021, v. 36, no. 2, p. 270-280
Abstract: This study aimed to evaluate an existing liquid-thickening guideline provided by a major manufacturer of thickener in Hong Kong and to provide directions for the implementation of the IDDSI framework. Fifteen participants who are naïve to liquid thickening were required to prepare thickened liquids samples from three drink bases (i.e., Milk-tea, Chinese tea, and Herbal tea) at two target consistency levels (i.e., mildly and medium/moderately thick) based on two guidelines (i.e., the manufacturer’s guideline and an IDDSI-driven guideline). Viscosities of the samples were measured rheologically to reflect liquid consistency. The manufacturer’s guideline resulted in distinguishable viscosities at the two consistency levels (F(1, 35.464) = 113.764, p < 0.001, ηp2 = 0.802), as well as different viscosities in different drink bases (F(1.267, 35.464 = 92.951, p < 0.001, ηp2 = 0.769). Comparison between the manufacturer’s and the IDDSI-driven guideline showed that the later resulted in more viscous liquid samples in all drink bases and at both consistency levels. The difference between the two guidelines was statistically significant (F(1,28) = 35.137, p < 0.001, ηp2 = 0.557). Following only the manufacturer’s guideline when thickening non-water beverages may lead to discrepancy between the resultant and prescribed consistencies. Thus, it should be considered inadequate to ensure swallowing safety. The effect of drink base should be emphasized to patients and caregivers, and pre-serving tests should be introduced. Despite similar classifications and terminologies used between the current local framework and the IDDSI framework, measures should be taken to avoid potential confusions and associated threats to swallowing safety.
Keywords: Deglutition disorders
Dysphagia
IDDSI
Liquid-thickening guidelines
Non-water local beverages
Viscosity
Publisher: Springer
Journal: Dysphagia 
ISSN: 0179-051X
EISSN: 1432-0460
DOI: 10.1007/s00455-020-10127-w
Rights: © Springer Science+Business Media, LLC, part of Springer Nature 2020
This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use (https://www.springernature.com/gp/open-research/policies/accepted-manuscript-terms), but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s00455-020-10127-w
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Kwong_IDDSI-driven_Non-water_Beverages.pdfPre-Published version1.75 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

73
Last Week
0
Last month
Citations as of Apr 14, 2025

Downloads

197
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

8
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

7
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.