Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/93387
Title: | Impact of inverter-based resources on negative sequence quantities-based protection elements | Authors: | Haddadi, A Zhao, M Kocar, I Karaagac, U Chan, KW Farantatos, E |
Issue Date: | Feb-2021 | Source: | IEEE transactions on power delivery, Feb. 2021, v. 36, no. 1, 9022918, p. 289-298 | Abstract: | Inverter-Based Resources (IBRs), including Wind turbine generators (WTGs), exhibit substantially different negative-sequence fault current characteristics compared to synchronous generators (SGs). These differences may cause misoperation of customary negative-sequence-based protective elements set under the assumption of a conventional SG dominated power system. The amplitude of the negative-sequence fault current of a WTG is smaller than that of an SG. This may lead to misoperation of the negative-sequence overcurrent elements 50Q/51Q. Moreover, the angular relation of the negative-sequence current and voltage is different under WTGs, which may result in the misoperation of directional negative-sequence overcurrent element 67Q. This paper first studies the key differences between the WTGs and SG by comparing their equivalent negative-sequence impedances with SG's. Then, simulation case studies are presented showing the misoperation of 50Q and 67Q due to wind generation and the corresponding impact on communication-assisted protection and fault identification scheme (FID). The impact on directional element is also experimentally validated in a hardware-in-the-loop real-time simulation set up using a physical relay. Finally, the paper studies the impact of various factors such as WTG type (Type-III/Type-IV) and Type-IV WTG control scheme (coupled/decoupled sequence) to determine the key features that need to be considered in practical protection studies. The objective is to show potential protection misoperation issues, identify the cause, and propose potential solutions. | Keywords: | Directional negative-sequence overcurrent Doubly-fed induction generator Full-size converter Inverter-based resource Negative sequence component Negative-sequence overcurrent protection Power system modeling Power system protection Wind farms |
Publisher: | Institute of Electrical and Electronics Engineers | Journal: | IEEE transactions on power delivery | ISSN: | 0885-8977 | EISSN: | 1937-4208 | DOI: | 10.1109/TPWRD.2020.2978075 | Rights: | © 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The following publication A. Haddadi, M. Zhao, I. Kocar, U. Karaagac, K. W. Chan and E. Farantatos, "Impact of Inverter-Based Resources on Negative Sequence Quantities-Based Protection Elements," in IEEE Transactions on Power Delivery, vol. 36, no. 1, pp. 289-298, Feb. 2021 is available at https://doi.org/10.1109/TPWRD.2020.2978075 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Karaagac_Impact_Inverter-Based_Resources.pdf | Pre-Published version | 1.55 MB | Adobe PDF | View/Open |
Page views
92
Last Week
0
0
Last month
Citations as of Apr 14, 2025
Downloads
280
Citations as of Apr 14, 2025
SCOPUSTM
Citations
115
Citations as of Apr 24, 2025
WEB OF SCIENCETM
Citations
60
Citations as of Oct 10, 2024

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.