Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/92958
Title: | Two-stage degradation and novel functional endothelium characteristics of a 3-D printed bioresorbable scaffold | Authors: | Yin, T Du, R Wang, Y Huang, J Ge, S Huang, Y Tan, Y Liu, Q Chen, Zhong Feng, H Du, J Wang, Y Wang, G |
Issue Date: | Apr-2022 | Source: | Bioactive materials, Apr. 2022, v. 10, p. 378-396 | Abstract: | Bioresorbable scaffolds have emerged as a new generation of vascular implants for the treatment of atherosclerosis, and designed to provide a temporary scaffold that is subsequently absorbed by blood vessels over time. Presently, there is insufficient data on the biological and mechanical responses of blood vessels accompanied by bioresorbable scaffolds (BRS) degradation. Therefore, it is necessary to investigate the inflexion point of degradation, the response of blood vessels, and the pathophysiological process of vascular, as results of such studies will be of great value for the design of next generation of BRS. In this study, abdominal aortas of SD rats were received 3-D printed poly-l-actide vascular scaffolds (PLS) for various durations up to 12 months. The response of PLS implanted aorta went through two distinct processes: (1) the neointima with desirable barrier function was obtained in 1 month, accompanied with slow degradation, inflammation, and intimal hyperplasia; (2) significant degradation occurred from 6 months, accompanied with decreasing inflammation and intimal hyperplasia, while the extracellular matrix recovered to normal vessels which indicate the positive remodeling. These in vivo results indicate that 6 months is a key turning point. This “two-stage degradation and vascular characteristics” is proposed to elucidate the long-term effects of PLS on vascular repair and demonstrated the potential of PLS in promoting endothelium function and positive remodeling, which highlights the benefits of PLS and shed some light in the future researches, such as drug combination coatings design. | Keywords: | Intravascular stents 3-D printing Bioresorbable scaffold Degradation behavior Functional endothelium |
Publisher: | Ke Ai Publishing Communications Ltd | Journal: | Bioactive materials | EISSN: | 2452-199X | DOI: | 10.1016/j.bioactmat.2021.08.020 | Rights: | © 2021 The Authors. Publishing services by Elsevier B.V. on behalf of KeAi Communications Co. Ltd. This is an open access article under the CCBY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). The following publication Yin, T., Du, R., Wang, Y., Huang, J., Ge, S., Huang, Y., ... & Wang, G. (2022). Two-stage degradation and novel functional endothelium characteristics of a 3-D printed bioresorbable scaffold. Bioactive materials, 10, 378-396 is available at https://doi.org/10.1016/j.bioactmat.2021.08.020 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
1-s2.0-S2452199X21003972-main.pdf | 7.93 MB | Adobe PDF | View/Open |
Page views
104
Last Week
0
0
Last month
Citations as of May 11, 2025
Downloads
109
Citations as of May 11, 2025
SCOPUSTM
Citations
33
Citations as of May 22, 2025
WEB OF SCIENCETM
Citations
27
Citations as of May 22, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.