Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/92793
| DC Field | Value | Language |
|---|---|---|
| dc.contributor | School of Optometry | en_US |
| dc.creator | Hon, Y | en_US |
| dc.creator | Wan, K | en_US |
| dc.creator | Chen, GZ | en_US |
| dc.creator | Lu, SH | en_US |
| dc.creator | Lam, DCC | en_US |
| dc.creator | Lam, AKC | en_US |
| dc.date.accessioned | 2022-05-18T02:43:22Z | - |
| dc.date.available | 2022-05-18T02:43:22Z | - |
| dc.identifier.issn | 0277-3740 | en_US |
| dc.identifier.uri | http://hdl.handle.net/10397/92793 | - |
| dc.language.iso | en | en_US |
| dc.publisher | Lippincott Williams & Wilkins | en_US |
| dc.rights | Copyright © 2016 Wolters Kluwer Health, Inc. All rights reserved. | en_US |
| dc.rights | This is the accepted version of an article published by Lippincott Williams & Wilkins in Cornea. To access the final edited and published work see https://doi.org/10.1097/ICO.0000000000000968 | en_US |
| dc.subject | Corneal biomechanics | en_US |
| dc.subject | Tangent modulus | en_US |
| dc.subject | Stiffness | en_US |
| dc.subject | Diurnal variation | en_US |
| dc.title | Diurnal variation of corneal tangent modulus in normal Chinese | en_US |
| dc.type | Journal/Magazine Article | en_US |
| dc.identifier.spage | 1600 | en_US |
| dc.identifier.epage | 1604 | en_US |
| dc.identifier.volume | 35 | en_US |
| dc.identifier.issue | 12 | en_US |
| dc.identifier.doi | 10.1097/ICO.0000000000000968 | en_US |
| dcterms.abstract | Purpose: The aim of this study was to investigate the diurnal variation of corneal tangent modulus, measured using a novel corneal indentation device, in healthy Chinese subjects. | en_US |
| dcterms.abstract | Methods: The central corneal thickness (CCT), mean central corneal radius (meanK), intraocular pressure (IOP), and corneal stiffness of 25 young adults aged 21 to 25 years (23.0 ± 1.0 yrs) were measured at 3-hour intervals from 09:00 to 21:00 in the course of 1 day. Corneal tangent modulus was calculated on the basis of corneal stiffness, CCT, and meanK. Repeated-measures analyses of variance were performed to compare the diurnal changes in ocular parameters over time. | en_US |
| dcterms.abstract | Results: Significant diurnal variations were observed in CCT and IOP (P < 0.001 and P = 0.025, respectively). Both parameters showed a decreasing trend throughout the day. MeanK and corneal stiffness did not show any significant diurnal changes (P = 0.251 and P = 0.516, respectively). Mean corneal tangent modulus across all measurements was 0.047 ± 0.085 MPa, and its diurnal rhythm ranged from 0.469 to 0.485 MPa. The variation was nonsignificant (P = 0.526). | en_US |
| dcterms.abstract | Conclusions: The elastic properties of the cornea in healthy Chinese subjects were stable during wake time. The present study shows that the corneal indentation device obtains stable corneal biomechanics similar to other clinical devices. Future studies investigating the differences in corneal biomechanics among patients with various ocular conditions are warranted. | en_US |
| dcterms.accessRights | open access | en_US |
| dcterms.bibliographicCitation | Cornea, Dec. 2016, v. 35, no. 12, p. 1600-1604 | en_US |
| dcterms.isPartOf | Cornea | en_US |
| dcterms.issued | 2016-12 | - |
| dc.identifier.isi | WOS:000387863300025 | - |
| dc.identifier.scopus | 2-s2.0-84983060355 | - |
| dc.identifier.pmid | 27538192 | - |
| dc.identifier.eissn | 1536-4798 | en_US |
| dc.description.validate | 202205 bcwh | en_US |
| dc.description.oa | Accepted Manuscript | en_US |
| dc.identifier.FolderNumber | SO-0084 | - |
| dc.description.fundingSource | Self-funded | en_US |
| dc.description.pubStatus | Published | en_US |
| dc.identifier.OPUS | 6669710 | - |
| dc.description.oaCategory | Green (AAM) | en_US |
| Appears in Collections: | Journal/Magazine Article | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Wan_Diurnal_Variation_Corneal.pdf | Pre-Published version | 544.32 kB | Adobe PDF | View/Open |
Page views
80
Last Week
0
0
Last month
Citations as of Apr 14, 2025
Downloads
108
Citations as of Apr 14, 2025
SCOPUSTM
Citations
13
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
12
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.