Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/91372
Title: | Time-variant positive air pressure in drainage stacks as a pathogen transmission pathway of COVID-19 | Authors: | Wong, LT Mui, KW Cheng, CL Leung, PHM |
Issue Date: | Jun-2021 | Source: | International journal of environmental research and public health, June 2021, v. 18, no. 11, 6068 | Abstract: | Time-variant positive air pressure in a drainage stack poses a risk of pathogenic virus transmission into a habitable space, however, the excessive risk and its significance have not yet been sufficiently addressed for drainage system designs. This study proposes a novel measure for the probable pathogenic virus transmission risk of a high-rise drainage stack with the occurrence of positive air pressure. The proposed approach is based on time-variant positive air pressures measured in a 38 m high drainage stack of a full-scale experimental tower under steady flow conditions of flow rate 1–4 Ls−1 discharging at a height between 15 m to 33 m above the stack base. The maximum pressure and probabilistic positive air pressures in the discharging stack ventilation section with no water (Zone A of the discharging drainage stack) were determined. It was demonstrated that the positive air pressures were lower in frequency as compared with those in other stack zones and could propagate along the upper 1/3 portion of the ventilation pipe (H’ ≥ 0.63) towards the ventilation opening at the rooftop. As the probabilistic positive pressures at a stack height were found to be related to the water discharging height and flow rate, a risk model of positive air pressure is proposed. Taking the 119th, 124th, 140th and 11,547th COVID-19 cases of an epidemiological investigation in Hong Kong as a baseline of concern, excessive risk of system overuse was evaluated. The results showed that for a 20–80% increase in the frequency of discharge flow rate, the number of floors identified at risk increased from 1 to 9 and 1 to 6 in the 34-and 25-storey residential buildings, respectively. The outcome can apply to facilities planning for self-quarantine arrangements in high-rise buildings where pathogenic virus transmission associated with drainage system overuse is a concern. | Keywords: | COVID-19 Drainage stack Experiment High-rise Pathogen transmission Positive air pressure |
Publisher: | Molecular Diversity Preservation International (MDPI) | Journal: | International journal of environmental research and public health | ISSN: | 1661-7827 | EISSN: | 1660-4601 | DOI: | 10.3390/ijerph18116068 | Rights: | © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/4.0/). The following publication Wong, L.-T.; Mui, K.-W.; Cheng, C.-L.; Leung, P.H.-M. Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19. Int. J. Environ. Res. Public Health 2021, 18, 6068 is available at https://doi.org/10.3390/ijerph18116068 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ijerph-18-06068.pdf | 3.26 MB | Adobe PDF | View/Open |
Page views
16
Last Week
1
1
Last month
Citations as of May 28, 2023
Downloads
6
Citations as of May 28, 2023
SCOPUSTM
Citations
6
Citations as of May 25, 2023
WEB OF SCIENCETM
Citations
6
Citations as of May 25, 2023

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.