Title: Enhancement of DC-bus voltage regulation in cascaded converter system by a new sensorless load current feedforward control scheme
Authors: Ali, M
Yaqoob, M
Cao, LL
Loo, KH 
Issue Date: Jun-2021
Source: IET power electronics, 17 June 2021
Abstract: It is generally known that, with conventional PI control, the stability and dynamic response performances of a power converter cannot be optimized simultaneously. To overcome this limitation, an uncertainty and disturbance estimator assisted sensorless load current feedforward control for dc-bus voltage regulation is presented to achieve fast dynamic response to load variations while stability is guaranteed by tuning PI controller. The proposed control scheme is verified on a cascaded converters system comprising a front end dc-dc DAB converter followed by a single-phase inverter as an illustrative case. Load-current feedforward is used to enhance the transient response of the front end DAB converter while an uncertainty and disturbance estimator is used to compensate for any non-idealities arising from model uncertainties and error in load current estimation. To validate the proposed control scheme, experimental results obtained from a 250-W cascaded converter system are presented and compared rigorously to the performance of conventional PI control.
Publisher: Institution of Engineering and Technology
Journal: IET power electronics 
ISSN: 1755-4535
EISSN: 1755-4543
DOI: 10.1049/pel2.12123
Rights: © 2021 The Authors. IET Power Electronics published by John Wiley & Sons Ltd on behalf of The Institution of Engineering and Technology
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
The following publication Ali M, Yaqoob M, Cao L, Loo K-H. Enhancement of DC-bus voltage regulation in cascaded converter system by a new sensorless load current feedforward control scheme. IET Power Electron. 2021;14:1457–1467 is available at https://doi.org/10.1049/pel2.12123
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Loo_Enhancement_DC-bus_voltage.pdf3.82 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

130
Last Week
2
Last month
Citations as of Nov 10, 2025

Downloads

133
Citations as of Nov 10, 2025

SCOPUSTM   
Citations

7
Citations as of Jun 21, 2024

WEB OF SCIENCETM
Citations

7
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.