Title: Effects of end distance on thin sheet steel single shear bolted connections at elevated temperatures
Authors: Cai, Y 
Young, B 
Issue Date: Mar-2020
Source: Thin-walled structures, 2020, v. 148, 106577, p. 1-14
Abstract: Thin sheet steel (TSS) single shear bolted connections at elevated temperatures were investigated experimentally in this study. The TSS 0.42 mm G550 and 1.90 mm G450 were used to fabricate the connection specimens. The connection specimens were designed with the variation of end distance. The specimens were tested at 5 different nominal temperature levels up to 900 °C using the steady state test method. The effects of end distance and temperature on the behaviour of bolted connections were investigated. It was found that the ultimate loads increased with the increment of the end distance up to three times the bolt diameter. Generally, the deteriorations of the connection strengths are in a similar manner to the corresponding material properties at elevated temperatures. The experimental results were compared with the predictions by using the Australian/New Zealand Standard (AS/NZS), European Code (EC3-1.3) and North American Specification (NAS) for cold-formed steel structures. In calculating the nominal strengths of the connections, the reduced material properties of TSS obtained at elevated temperatures were used. Overall, it is shown that the predictions from the AS/NZS, NAS and EC3-1.3 are conservative, with the AS/NZS providing the least conservative and least scattered predictions. However, the reliability analysis showed that the design provisions of the three design specifications are not reliable for the TSS single shear bolted connections in this study, with considerable scope for the development of improved design formulae. Generally, the AS/NZS and NAS could provide accurate predictions of failure modes for TSS connection specimens failed in tearout failure and bearing failure at different temperature levels.
Keywords: Bearing failure
Bolted connection
Elevated temperatures
Experimental investigation
Tearout failure
Thin sheet steel
Publisher: Pergamon Press
Journal: Thin-walled structures 
ISSN: 0263-8231
EISSN: 1879-3223
DOI: 10.1016/j.tws.2019.106577
Rights: © 2020 Elsevier Ltd. All rights reserved.
© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Cai, Y., & Young, B. (2020). Effects of end distance on thin sheet steel single shear bolted connections at elevated temperatures. Thin-Walled Structures, 148, 106577 is available at https://dx.doi.org/10.1016/j.tws.2019.106577.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Cai_Effects_Distance_Thin.pdfPre-Published version1.71 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

110
Last Week
1
Last month
Citations as of Mar 24, 2024

Downloads

26
Citations as of Mar 24, 2024

SCOPUSTM   
Citations

8
Citations as of Mar 28, 2024

WEB OF SCIENCETM
Citations

7
Citations as of Mar 28, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.