Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/88069
PIRA download icon_1.1View/Download Full Text
Title: Testing impacts of global blur profiles using a multiscale vision simulator
Authors: De Lestrange-Anginieur, E 
Kee, CS 
Issue Date: Jul-2020
Source: Heliyon, July 2020, v. 6, no. 7, e04153, p. 1-9
Abstract: Although it is possible to specify the impact of blur at a specific retinal location, a lack of understanding exists regarding how the inhomogeneous blur distribution across the retina (i.e., global blur) affects the quality of an optical correction at a specific retinal location. To elucidate this issue, a multiscale visual simulator combining the projection of a controllable high-resolution stimulus and an ocular monitoring system was constructed to simultaneously simulate foveal and extrafoveal blurs. To define the range and capability of a wide-angle stimulation, an optimal working pupil was evaluated by optical ray-tracing via a Monte Carlo simulation, including optical variations corresponding to fixational eye movements. To investigate the impacts of global blur on the perception of discrete regions of the visual field, the bothersome blur threshold from five subjects was measured through this novel system using a collection of zonal blurs (annuli image projected sequentially at discrete retinal regions), and these impacts were compared with those using a spatially-varying blur (continuum of simultaneously projected zonal blurs of varying strengths, simulating retinal blur variations). Our results show that the zonal blur threshold does not entirely predict the global blur threshold, having a tendency to overestimate blur the threshold. It was concluded that, in addition to the amount of defocus present at a defined retinal location, the perception of individual defocused retinal regions can be affected by global blur. Given that blur tolerance can affect the perception of optically induced blurs, the findings provide useful implications for designing new optical correction.
Keywords: Biomedical engineering
Optics
Blur
Spatial interaction
Isoplanaticity
Visual field
Observer method
Publisher: Elsevier
Journal: Heliyon 
EISSN: 2405-8440
DOI: 10.1016/j.heliyon.2020.e04153
Rights: ©2020 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
The following publication De Lestrange-Anginieur, E., & Kee, C. S. (2020). Testing impacts of global blur profiles using a multiscale vision simulator. Heliyon, 6(7), 1-9 is available at https://dx.doi.org/10.1016/j.heliyon.2020.e04153
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
De_Lestrange-Anginieur_Testing_Blur.pdf2.32 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

78
Last Week
2
Last month
Citations as of Apr 14, 2024

Downloads

48
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

2
Citations as of Apr 5, 2024

WEB OF SCIENCETM
Citations

1
Last Week
1
Last month
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.