Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/87770
| Title: | Volumetric cine magnetic resonance imaging (VC-MRI) using motion modeling, free-form deformation and multi-slice undersampled 2D cine MRI reconstructed with spatio-temporal low-rank decomposition | Authors: | Harris, W Yin, FF Cai, J Ren, L |
Issue Date: | Feb-2020 | Source: | Quantitative imaging in medicine and surgery, Feb. 2020, v. 10, no. 2, p. 432-450 | Abstract: | Background: The purpose of this study is to improve on-board volumetric cine magnetic resonance imaging (VC-MRI) using multi-slice undersampled tine images reconstructed using spatio-temporal k-space data, patient prior 4D-MRI, motion modeling (MM) and free-form deformation (FD) for real-time 3D target verification of liver and lung radiotherapy. Methods: A previous method was developed to generate on-board VC-MRI by deforming prior MRI images based on a MM and a single for m01-06 =m05-slice on-board 2D-cine image. The two major improvements over the previous method are: (I) FD was introduced to estimate VC-MRI to correct for inaccuracies in the MM; (II) multi-slice undersampled 2D-cine images reconstructed by a k-t SLR reconstruction method were used for FD-based estimation to maintain the temporal resolution while improving the accuracy of VC-MRI. The method was evaluated using XCAT lung simulation and four liver patients' data. Results: For XCAT, VC-MRI estimated using ten undersampled sagittal 2D-Line MRIs resulted in volume percent difference/volume dice coefficient/center-of-mass shift of 9.77%+/- 3.71%/0.95 +/- 0.02/0.75 +/- 0.26 mm among all scenarios based on estimation with MM and FD. Adding FD optimization improved VC-MRI accuracy substantially for scenarios with anatomical changes. For patient data, the mean tumor tracking errors were 0.64 +/- 0.51, 0.62 +/- 0.47 and 0.24 +/- 0.24 mm along the superior-inferior (SI), anterior-posterior (AP) and lateral directions, respectively, across all liver patients. Conclusions: It is feasible to improve VC-MRI accuracy while maintaining high temporal resolution using FD and multi-slice undersampled 2D cinc images for real-time 3D target verification. |
Keywords: | Volumetric-cine magnetic resonance imaging (volumetric-cine MRI) Target verification Motion modeling Free-form deformation K-t SLR reconstruction |
Publisher: | AME Publishing Company | Journal: | Quantitative imaging in medicine and surgery | ISSN: | 2223-4292 | EISSN: | 2223-4306 | DOI: | 10.21037/qims.2019.12.10 | Rights: | All content of the AME journals is published with open access under the Creative Commons Attribution-NonCommercial-NoDerivs License (CC BY-NC-ND 4.0). All articles published under open access will be immediately and permanently free for everyone to read, download, copy, and distribute as defined by the applied license. The full details of the license are available at https://creativecommons.org/licenses/by-nc-nd/4.0/ © Quantitative Imaging in Medicine and Surgery. All rights reserved. The following publication Harris W, Yin FF, Cai J, Ren L. Volumetric cine magnetic resonance imaging (VC-MRI) using motion modeling, free-form deformation and multi-slice undersampled 2D cine MRI reconstructed with spatio-temporal low-rank decomposition. Quant Imaging Med Surg 2020;10(2):432-450. doi: 10.21037/qims.2019.12.10 is available at https://dx.doi.org/10.21037/qims.2019.12.10 |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Harris_Vc-Mri_Free-Form_Deformation.pdf | 2.02 MB | Adobe PDF | View/Open |
Page views
83
Last Week
0
0
Last month
Citations as of Apr 14, 2025
Downloads
21
Citations as of Apr 14, 2025
SCOPUSTM
Citations
15
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
15
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



