Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/81710
DC Field | Value | Language |
---|---|---|
dc.contributor | Institute of Textiles and Clothing | - |
dc.creator | Zou, Z | - |
dc.creator | Shen, HL | - |
dc.creator | Zhu, YF | - |
dc.creator | Xin, JH | - |
dc.date.accessioned | 2020-02-10T12:28:45Z | - |
dc.date.available | 2020-02-10T12:28:45Z | - |
dc.identifier.uri | http://hdl.handle.net/10397/81710 | - |
dc.language.iso | en | en_US |
dc.publisher | Molecular Diversity Preservation International (MDPI) | en_US |
dc.rights | © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). | en_US |
dc.rights | The following publication Zou, Z.; Shen, H.-L.; Li, S.; Zhu, Y.; Xin, J.H. Lighting Deviation Correction for Integrating-Sphere Multispectral Imaging Systems. Sensors 2019, 19, 3501, 1-13 is available at https://dx.doi.org/10.3390/s19163501 | en_US |
dc.subject | Multispectral imaging | en_US |
dc.subject | Integrating sphere | en_US |
dc.subject | Lighting deviation | en_US |
dc.subject | Spectral reflectance | en_US |
dc.title | Lighting deviation correction for integrating-sphere multispectral imaging systems | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.identifier.spage | 1 | - |
dc.identifier.epage | 13 | - |
dc.identifier.volume | 19 | - |
dc.identifier.issue | 16 | - |
dc.identifier.doi | 10.3390/s19163501 | - |
dcterms.abstract | In an integrating sphere multispectral imaging system, measurement inconsistency can arise when acquiring the spectral reflectances of samples. This is because the lighting condition can be changed by the measured samples, due to the multiple light reflections inside the integrating sphere. Besides, owing to non-uniform light transmission of the lens and narrow-band filters, the measured reflectance is spatially dependent. To deal with these problems, we propose a correction method that consists of two stages. The first stage employs a white board to correct non-uniformity and a small white patch to correct lighting deviation, both under the assumption of ideal Lambertian reflection. The second stage uses a polynomial regression model to further remove the lighting inconsistency when measuring non-Lambertian samples. The method is evaluated on image data acquired in a real multispectral imaging system. Experimental results illustrate that our method eliminates the measurement inconsistency considerably. This consequently improves the spectral and colorimetric accuracy in color measurement, which is crucial to practical applications. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Sensors, 20 Aug. 2019, v. 19, no. 16, 3501, p. 1-13 | - |
dcterms.isPartOf | Sensors | - |
dcterms.issued | 2019 | - |
dc.identifier.isi | WOS:000484407200058 | - |
dc.identifier.eissn | 1424-8220 | - |
dc.identifier.artn | 3501 | - |
dc.description.validate | 202002 bcrc | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_Scopus/WOS | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | CC | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Zou_Lighting_Deviation_Correction.pdf | 1.17 MB | Adobe PDF | View/Open |
Page views
150
Last Week
1
1
Last month
Citations as of Apr 13, 2025
Downloads
86
Citations as of Apr 13, 2025
SCOPUSTM
Citations
2
Citations as of Jun 21, 2024
WEB OF SCIENCETM
Citations
1
Citations as of May 8, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.