Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/81263
Title: | Reliability, validity and minimal detectable change of 2-min walk test and 10-m walk test in frail older adults receiving day care and residential care | Authors: | Chan, WLS Pin, TW |
Issue Date: | Apr-2020 | Source: | Aging clinical and experimental research, Apr. 2020, v. 32, no. 11, p. 597-604 | Abstract: | Background: The psychometric properties of the 2-min walk test (2MWT) and 10-m walk test (10MeWT) for frail older adults are unclear. Aims: To determine the test–retest and inter-rater reliability, construct and known-group validity, and minimal detectable change at 95% level of confidence (MDC95) of these walk tests in frail older adults receiving day care and residential care services. Methods: A cross-sectional study with repeated measures was conducted on frail older adults who could walk independently for at least 15 m. The participants completed the 2MWT and 10MeWT on three separate occasions over a 2-week period under two independent assessors. Results: Forty-four frail older adults were examined. Excellent test-rest (ICC = 0.95–0.99) and inter-rater reliability (ICC = 0.95–0.97) were shown in both walk tests. Good to strong correlations were found between the walk tests and 6-min walk test (r = 0.89–0.92), Elderly Mobility Scale (r = 0.56–0.57), Berg Balance Scale (r = 0.66–0.66) and Modified Barthel Index (r = 0.55–0.59). The MDC95 were 7.7 m in the 2MWT and 0.13 m/s in the 10MeWT. Discussion: Although the walking performances of the day care and residential care participants were similar, the validity of the walk tests was different between these two subgroups. Conclusions: The 2MWT and 10MeWT are reliable and valid measures in evaluating the walking performances of frail older adults. The MDC95 of the walk tests has been recommended. |
Keywords: | Exercise test Outcome assessment Psychometric study Rehabilitation Walking |
Publisher: | Springer | Journal: | Aging clinical and experimental research | ISSN: | 1594-0667 | EISSN: | 1720-8319 | DOI: | 10.1007/s40520-019-01255-x | Rights: | © Springer Nature Switzerland AG 2019 This is a post-peer-review, pre-copyedit version of an article published in Aging Clinical and Experimental Research. The final authenticated version is available online at: https://doi.org/10.1007/s40520-019-01255-x. |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Manuscript_WalkTest_Frail_AgingClinical_PostPrint.pdf | Pre-Published version | 934.83 kB | Adobe PDF | View/Open |
ONLINE RESOURCE 1_PostPrint.pdf | Pre-Published version | 710.84 kB | Adobe PDF | View/Open |
Page views
129
Last Week
0
0
Last month
Citations as of Jun 4, 2023
Downloads
150
Citations as of Jun 4, 2023
SCOPUSTM
Citations
9
Citations as of Jun 8, 2023
WEB OF SCIENCETM
Citations
9
Citations as of Jun 8, 2023

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.