Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/80507
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Health Technology and Informatics | - |
dc.contributor | Institute of Textiles and Clothing | - |
dc.contributor | School of Nursing | - |
dc.creator | Suen, LKP | - |
dc.creator | Guo, YP | - |
dc.creator | Tong, DWK | - |
dc.creator | Leung, PHM | - |
dc.creator | Lung, D | - |
dc.creator | Ng, MSP | - |
dc.creator | Lai, TKH | - |
dc.creator | Lo, KYK | - |
dc.creator | Au-Yeung, CH | - |
dc.creator | Yu, W | - |
dc.date.accessioned | 2019-03-26T09:17:36Z | - |
dc.date.available | 2019-03-26T09:17:36Z | - |
dc.identifier.uri | http://hdl.handle.net/10397/80507 | - |
dc.language.iso | en | en_US |
dc.publisher | BioMed Central | en_US |
dc.rights | © The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. | en_US |
dc.rights | The following publication Suen, L. K. P., Guo, Y. P., Tong, D. W. K., Leung, P. H. M., Lung, D., Ng, M. S. P., . . . Yu, W. N. (2018). Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission. Antimicrobial Resistance and Infection Control, 7, 157, 1-9 is available at https://dx.doi.org/10.1186/s13756-018-0433-y | en_US |
dc.title | Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.identifier.spage | 1 | en_US |
dc.identifier.epage | 9 | en_US |
dc.identifier.volume | 7 | en_US |
dc.identifier.doi | 10.1186/s13756-018-0433-y | en_US |
dcterms.abstract | Background: Healthcare workers (HCWs) use personal protective equipment (PPE) in Ebola virus disease (EVD) situations. However, preventing the contamination of HCWs and the environment during PPE removal crucially requires improved strategies. This study aimed to compare the efficacy of three PPE ensembles, namely, Hospital Authority (HA) Standard Ebola PPE set (PPE1), Dupont Tyvek Model, style 1422A (PPE2), and HA isolation gown for routine patient care and performing aerosol-generating procedures (PPE3) to prevent EVD transmission by measuring the degree of contamination of HCWs and the environment. | - |
dcterms.abstract | Methods: A total of 59 participants randomly performed PPE donning and doffing. The trial consisted of PPE donning, applying fluorescent solution on the PPE surface, PPE doffing of participants, and estimation of the degree of contamination as indicated by the number of fluorescent stains on the working clothes and environment. Protocol deviations during PPE donning and doffing were monitored. | - |
dcterms.abstract | Results: PPE2 and PPE3 presented higher contamination risks than PPE1. Environmental contaminations such as those originating from rubbish bin covers, chairs, faucets, and sinks were detected. Procedure deviations were observed during PPE donning and doffing, with PPE1 presenting the lowest overall deviation rate (%) among the three PPE ensembles (p < 0.05). | - |
dcterms.abstract | Conclusion: Contamination of the subjects’ working clothes and surrounding environment occurred frequently during PPE doffing. Procedure deviations were observed during PPE donning and doffing. Although PPE1 presented a lower contamination risk than PPE2 and PPE3 during doffing and protocol deviations, the design of PPE1 can still be further improved. Future directions should focus on designing a high-coverage-area PPE with simple ergonomic features and on evaluating the doffing procedure to minimise the risk of recontamination. Regular training for users should be emphasised to minimise protocol deviations, and in turn, guarantee the best protection to HCWs. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Antimicrobial resistance and infection control, 22 Dec. 2018, v. 7, 157, p. 1-9 | - |
dcterms.isPartOf | Antimicrobial resistance and infection control | - |
dcterms.issued | 2018 | - |
dc.identifier.isi | WOS:000454205100001 | - |
dc.identifier.scopus | 2-s2.0-85058940767 | - |
dc.identifier.pmid | 30607244 | - |
dc.identifier.ros | 2018000066 | - |
dc.identifier.eissn | 2047-2994 | en_US |
dc.identifier.artn | 157 | en_US |
dc.description.validate | 201903 bcrc | en_US |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | a0307-n02 | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | CC | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Suen_Self-contamination_Doffing_Protective.pdf | 624.94 kB | Adobe PDF | View/Open |
Page views
236
Last Week
0
0
Last month
Citations as of Sep 1, 2024
Downloads
107
Citations as of Sep 1, 2024
SCOPUSTM
Citations
79
Citations as of Aug 29, 2024
WEB OF SCIENCETM
Citations
76
Citations as of Aug 29, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.