Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/77085
Title: | Effects of pulsed electromagnetic field (PEMF) on the tensile biomechanical properties of diabetic wounds at different phases of healing | Authors: | Choi, HMC Cheung, AKK Ng, GYF Cheing, GLY |
Issue Date: | 2018 | Source: | PLoS one, 2018, v. 13, no. 1, e0191074 | Abstract: | The present study investigated the effects of pulsed electromagnetic field (PEMF) on the tensile biomechanical properties of diabetic wounds at different phases of healing. Two intensities of PEMF were adopted for comparison. We randomly assigned 111 10-week-old male streptozotocin-induced diabetic Sprague-Dawley rats to two PEMF groups and a sham control group. Six-millimetre biopsy punched full thickness wounds were made on the lateral side of their hindlimbs. The PEMF groups received active PEMF delivered at 25 Hz with intensity of either 2 mT or 10 mT daily, while the sham group was handled in a similar way except they were not exposed to PEMF. Wound tissues were harvested for tensile testing on post-wounding days 3, 5, 7, 10, 14 and 21. Maximum load, maximum stress, energy absorption capacity, Young’s modulus and thickness of wound tissue were measured. On post-wounding day 5, the PEMF group that received 10-mT intensity had significantly increased energy absorption capacity and showed an apparent increase in the maximum load. However, the 10-mT PEMF group demonstrated a decrease in Young’s modulus on day 14. The 10-mT PEMF groups showed a significant increase in the overall thickness of wound tissue whereas the 2-mT group showed a significant decrease in the overall maximum stress of the wounds tissue. The present findings demonstrated that the PEMF delivered at 10 mT can improve energy absorption capacity of diabetic wounds in the early healing phase. However, PEMF (both 2-mT and 10-mT) seemed to impair the material properties (maximum stress and Young’s modulus) in the remodelling phase. PEMF may be a useful treatment for promoting the recovery of structural properties (maximum load and energy absorption capacity), but it might not be applied at the remodelling phase to avoid impairing the recovery of material properties. | Publisher: | Public Library of Science | Journal: | PLoS one | EISSN: | 1932-6203 | DOI: | 10.1371/journal.pone.0191074 | Description: | Correction: Effects of pulsed electromagnetic field (PEMF) on the tensile biomechanical properties of diabetic wounds at different phases of healing. PLOS ONE 13(11): e0208475. https://doi.org/10.1371/journal.pone.0208475 https://ira.lib.polyu.edu.hk/handle/10397/89537 |
Rights: | © 2018 Choi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. The following publication: Choi HMC, Cheing AKK, Ng GYF, Cheing GLY (2018) Effects of pulsed electromagnetic field (PEMF) on the tensile biomechanical properties of diabetic wounds at different phases of healing. PLoS ONE 13(1): e0191074 is available at https://doi.org/10.1371/journal.pone.0191074 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
journal.pone.0191074.pdf | 655.26 kB | Adobe PDF | View/Open |
Page views
175
Last Week
2
2
Last month
Citations as of Dec 22, 2024
Downloads
110
Citations as of Dec 22, 2024
SCOPUSTM
Citations
19
Last Week
0
0
Last month
Citations as of Dec 19, 2024
WEB OF SCIENCETM
Citations
12
Last Week
0
0
Last month
Citations as of Dec 19, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.