Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/71127
Title: | Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients | Authors: | Lin, CG Xu, SK Yao, WY Wu, YQ Fang, JL Wu, VWC |
Issue Date: | Jun-2017 | Source: | Journal of medical radiation sciences, June 2017, v. 64, no. 2, p. 106-113 | Abstract: | Introduction: In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. Methods: Patients were randomly assigned to one of the three immobilisation systems: (1) supine on head rest and base plate (HB)MergeCell (2) supine with alpha cradle supporting the head and shoulder (AC)MergeCell (3) supine with vacuum bag supporting the head and shoulder (VB). CBCT was conducted weekly for each patient on the linear accelerator. Image registration was conducted at the nasopharynx (NP) and cervical regions. The translational displacements (latero-medial, antero-posterior and cranio-caudal), rotational displacements (pitch, yaw and roll) and 3D vectors obtained at the NP and cervical regions were recorded and compared among the three systems. Results: The mean translational and rotational deviations were within 3 mm and 2°, respectively, and the range of 3D vector was 1.53–3.47 mm. At the NP region, the AC system demonstrated the smallest translational and rotational deviations and 3D vector. The differences were significant except for the latero-medial, yaw and roll directions. Similarly, at the cervical region, the AC system showed smaller translational and rotational deviations and 3D vector, with only the cranio-caudal and yaw deviations that did not reach statistical significance. Conclusions: Set up deviation was greater in the neck than the NP region. The set up accuracy of the AC system was better than the other two systems, and it is recommended for IMRT of NPC patients in our institution. | Keywords: | Cone beam CT Immobilisation system Intensity modulated radiotherapy Nasopharyngeal carcinoma Set up accuracy |
Publisher: | John Wiley & Sons | Journal: | Journal of medical radiation sciences | ISSN: | 2051-3895 | DOI: | 10.1002/jmrs.189 | Rights: | © 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and
no modifications or adaptations are made. The following publication Lin, C. G., Xu, S. K., Yao, W. Y., Wu, Y. Q., Fang, J. L., & Wu, V. W. (2017). Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients. Journal of medical radiation sciences, 64(2), 106-113 is available at https://doi.org/10.1002/jmrs.189 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Lin_Comparison__Set_Accuracy.pdf | 934.86 kB | Adobe PDF | View/Open |
Page views
76
Last Week
1
1
Last month
Citations as of Nov 22, 2023
Downloads
9
Citations as of Nov 22, 2023
SCOPUSTM
Citations
17
Last Week
0
0
Last month
Citations as of Nov 23, 2023

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.