Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/6510
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Electrical Engineering | - |
dc.creator | Gong, JM | - |
dc.creator | MacAlpine, M | - |
dc.creator | Jin, W | - |
dc.creator | Liao, YB | - |
dc.date.accessioned | 2014-12-11T08:25:11Z | - |
dc.date.available | 2014-12-11T08:25:11Z | - |
dc.identifier.issn | 0003-6935 | - |
dc.identifier.uri | http://hdl.handle.net/10397/6510 | - |
dc.language.iso | en | en_US |
dc.publisher | Optical Society of America | en_US |
dc.rights | © 2001 Optical Society of America. This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/ao/abstract.cfm?URI=ao-40-34-6199. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law. | en_US |
dc.subject | Acoustic emission testing | en_US |
dc.subject | Electromagnetic fields | en_US |
dc.subject | Interferometers | en_US |
dc.subject | Light sources | en_US |
dc.subject | Multiplexing | en_US |
dc.subject | Oil filled transformers | en_US |
dc.title | Locating acoustic emission with an amplitude-multiplexed acoustic sensor array based on a modified Mach-Zehnder interferometer | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.description.otherinformation | Author name used in this publication: Jianmin Gong | en_US |
dc.description.otherinformation | Author name used in this publication: J. M. K. MacAlpine | en_US |
dc.description.otherinformation | Author name used in this publication: Yanbiao Liao | en_US |
dc.identifier.spage | 6199 | - |
dc.identifier.epage | 6202 | - |
dc.identifier.volume | 40 | - |
dc.identifier.issue | 34 | - |
dc.identifier.doi | 10.1364/AO.40.006199 | - |
dcterms.abstract | We report on an amplitude-division-multiplexed interferometric sensor array for locating acoustic emission. Preliminary experiments were carried out with a modified Mach-Zehnder interferometer consisting of two sensing arms and a reference arm and demonstrated a one-dimensional location accuracy of a few centimeters. The system can be extended for two- and three-dimensional location of acoustic emissions by the addition of one or two more sensing arms, respectively, in the interferometer. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Applied optics, 1 Dec. 2001, v. 40, no. 34, p. 6199-6202 | - |
dcterms.isPartOf | Applied optics | - |
dcterms.issued | 2001-12-01 | - |
dc.identifier.isi | WOS:000172713000008 | - |
dc.identifier.scopus | 2-s2.0-0037811965 | - |
dc.identifier.rosgroupid | r05801 | - |
dc.description.ros | 2001-2002 > Academic research: refereed > Publication in refereed journal | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | VoR allowed | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Gong_Acoustic_Amplitude-multiplexed_.pdf | 86.23 kB | Adobe PDF | View/Open |
Page views
516
Last Week
2
2
Last month
Citations as of Apr 13, 2025
Downloads
187
Citations as of Apr 13, 2025
SCOPUSTM
Citations
22
Last Week
0
0
Last month
0
0
Citations as of May 8, 2025
WEB OF SCIENCETM
Citations
19
Last Week
0
0
Last month
0
0
Citations as of May 8, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.