Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/616
| DC Field | Value | Language |
|---|---|---|
| dc.contributor | Department of Applied Physics | - |
| dc.creator | Guo, S | - |
| dc.creator | Chan, HLW | - |
| dc.creator | Zhao, X | - |
| dc.creator | Choy, CL | - |
| dc.date.accessioned | 2014-12-11T08:28:16Z | - |
| dc.date.available | 2014-12-11T08:28:16Z | - |
| dc.identifier.issn | 0034-6748 | - |
| dc.identifier.uri | http://hdl.handle.net/10397/616 | - |
| dc.language.iso | en | en_US |
| dc.publisher | American Institute of Physics | en_US |
| dc.rights | © 2003 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in S. Guo et al., Rev. Sci. Instrum. 74, 1285 (2003) and may be found at http://link.aip.org/link/?rsi/74/1285. | en_US |
| dc.subject | Polymer films | en_US |
| dc.subject | Strain sensors | en_US |
| dc.subject | Extensometers | en_US |
| dc.subject | Piezoelectric transducers | en_US |
| dc.title | Factors affecting the performance of the bimorph-based dilatometer for field induced strain measurement of polymer films | en_US |
| dc.type | Journal/Magazine Article | en_US |
| dc.description.otherinformation | Author name used in this publication: H. L. W. Chan | en_US |
| dc.description.otherinformation | Author name used in this publication: X.-Z. Zhao | en_US |
| dc.description.otherinformation | Author name used in this publication: C. L. Choy | en_US |
| dc.identifier.spage | 1285 | - |
| dc.identifier.epage | 1291 | - |
| dc.identifier.volume | 74 | - |
| dc.identifier.issue | 3 | - |
| dcterms.abstract | This article gives a detailed discussion about the design and performance of a bimorph-based dilatometer using different sensor heads and platforms both experimentally and theoretically. A current preamplifier in high-pass filter mode was used to optimize the signal and a protective circuit was introduced. The test results demonstrated that the best signal occurred when the lengths of stainless steel pin and bimorph were both 10.0 mm and that the resonant frequency was inversely proportional to the square of the sensor length. Some suggestions for reducing the noise and improving the sensitivity were also provided. | - |
| dcterms.accessRights | open access | en_US |
| dcterms.bibliographicCitation | Review of scientific instruments, Mar. 2003, v. 74, no. 3, p. 1285-1291 | - |
| dcterms.isPartOf | Review of scientific instruments | - |
| dcterms.issued | 2003-03 | - |
| dc.identifier.isi | WOS:000181530300022 | - |
| dc.identifier.scopus | 2-s2.0-0037352001 | - |
| dc.identifier.eissn | 1089-7623 | - |
| dc.identifier.rosgroupid | r15114 | - |
| dc.description.ros | 2002-2003 > Academic research: refereed > Publication in refereed journal | - |
| dc.description.oa | Version of Record | en_US |
| dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
| dc.description.pubStatus | Published | en_US |
| dc.description.oaCategory | VoR allowed | en_US |
| Appears in Collections: | Journal/Magazine Article | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| bimorph-based_03.pdf | 328.38 kB | Adobe PDF | View/Open |
Page views
185
Last Week
1
1
Last month
Citations as of Oct 6, 2025
Downloads
244
Citations as of Oct 6, 2025
SCOPUSTM
Citations
1
Last Week
0
0
Last month
0
0
Citations as of Jun 21, 2024
WEB OF SCIENCETM
Citations
1
Last Week
0
0
Last month
0
0
Citations as of May 15, 2025
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.



