Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/60849
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Electrical Engineering-
dc.creatorLiu, MB-
dc.creatorLi, YH-
dc.creatorChan, KW-
dc.date.accessioned2016-12-19T08:53:12Z-
dc.date.available2016-12-19T08:53:12Z-
dc.identifier.issn1003-8930-
dc.identifier.urihttp://hdl.handle.net/10397/60849-
dc.language.isozhen_US
dc.publisher中国学术期刊(光盘版)电子杂志社en_US
dc.rights© 2007 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。en_US
dc.rights© 2007 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research use.en_US
dc.subjectSustainability developmenten_US
dc.subjectMotivating factorsen_US
dc.subjectTaiwan manufacturingen_US
dc.subjectHigh-tech firmsen_US
dc.titleTransient stability constrained optimal power flow using trajectory sensitivitiesen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage24-
dc.identifier.epage29-
dc.identifier.volume19-
dc.identifier.issue6-
dcterms.abstract为将暂态稳定约束最优潮流问题转化为最优潮流和暂态稳定两个子问题,根据暂态稳定计算结果求出 发电机转角及转速相对于机械输入功率的轨迹灵敏度。基于轨迹灵敏度,计算出在最领先发电机和最落后发 电机之间转移的有功功率,据此修改其在最优潮流模型中的有功功率上下限,从而实现两个子问题的交替求 解。并且推导出准确的轨迹灵敏度及初值计算公式,利用上述公式,得更小的转移功率值,从而使功率转移后 系统的优化程度更高。同时在惯性中心坐标下采用最大转角判据找出最领先机和最落后机,并以3机9节点和 10机39节点系统为例,验证了该方法的可行性。-
dcterms.abstractTransient stability constrained optimal power flow(TSC-OPF) problem is divided into two sub-problems,which are optimal power flow(OPF) and transient stability control.Trajectory sensitivities of both velocities and rotor angles of generators with respect to their mechanical input power are calculated according to the results of transient stability simulation.Shifting active power between the most critical machine and the least critical one to regain transient stability is obtained according to trajectory sensitivities,based on which upper and lower active power limits of generators in OPF model are modified and thus OPF problem and transient stability control can be performed iteratively.Accurate expressions of trajectory sensitivities and their initial values have been derived instead of using approximate ones by which smaller shifting active power can be obtained and thus a more optimal operation point of power system can be given.A biggest rotor angle criterion under the center of inertia reference frame is used to determine critical order of generators.Furthermore,results obtained from 3-machine 9-bus system and 10-machine 39-bus system validate the proposed method.-
dcterms.accessRightsopen accessen_US
dcterms.alternative基于轨迹灵敏度的暂态稳定约束最优潮流计-
dcterms.bibliographicCitation電力系統及其自動化學報 (Proceedings of the EPSA), 2007, v. 19, no. 6, p. 24-29-
dcterms.isPartOf電力系統及其自動化學報 (Proceedings of the EPSA)-
dcterms.issued2007-
dc.identifier.rosgroupidr37140-
dc.description.ros2007-2008 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryVoR alloweden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
r37140.pdf364.57 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

150
Last Week
2
Last month
Citations as of Nov 10, 2025

Downloads

368
Citations as of Nov 10, 2025

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.