Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/5919
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineering-
dc.creatorZheng, CY-
dc.creatorXiao, F-
dc.creatorChen, W-
dc.date.accessioned2014-12-11T08:25:50Z-
dc.date.available2014-12-11T08:25:50Z-
dc.identifier.issn1002-8528-
dc.identifier.urihttp://hdl.handle.net/10397/5919-
dc.language.isozhen_US
dc.publisher中國學術期刊(光盤版)電子雜誌社en_US
dc.rights© 2012 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。en_US
dc.rights© 2012 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research purposes.en_US
dc.subjectWater chilleren_US
dc.subjectFault detection and diagnosisen_US
dc.subjectModelen_US
dc.subjectData-drivenen_US
dc.title冷水机组故障诊断新模型en_US
dc.typeJournal/Magazine Articleen_US
dc.description.otherinformationTitle in Traditional Chinese: 冷水機組故障診斷新模型en_US
dc.description.otherinformationJournal title in Traditional Chinese: 建築科學en_US
dc.description.otherinformationAuthor name used in this publication: 郑超瑜en_US
dc.description.otherinformationAuthor name used in this publication: 肖赋en_US
dc.description.otherinformationAuthor name used in this publication: 陈武en_US
dc.identifier.spage104-
dc.identifier.epage107-
dc.identifier.volume28-
dc.identifier.issue12-
dcterms.abstract冷水机组在大型建筑物空调系统中得到了广泛应用,其故障诊断也受到了广泛关注。本文提出使用压缩机功耗、冷凝器负荷、虚拟蒸发器负荷以及虚拟冷凝器负荷替代蒸发器负荷,组成冷水机组故障诊断新模型,以满足不同参数条件下的故障诊断要求。通过ASHRAE 1043-RP 数据的验证,新模型具有很好的预测精度,能够作为冷水机组的故障诊断模型。-
dcterms.abstractWater chiller has been widely used in large building air-conditioning system,and its fault detection and diagnosis has received extensive attention. In this paper,c ompressor power consumption,c ondenser load,pseudo evaporator load and pseudo condenser load were used to replace real evaporator load to develop new reference models for fault detection and diagnosis in water chillers,these reference models could satisfy different fault detection and diagnosis requirements under different parameters. All developed reference models had good prediction accuracy through the validation of the data sets of ASHRAE 1043-RP,and could be used as alternative reference models for fault detection and diagnosis in water chillers.-
dcterms.accessRightsopen accessen_US
dcterms.alternativeNew reference models for fault detection and diagnose in water chillers-
dcterms.bibliographicCitation建筑科学 (Building science), Dec. 2012, v. 28, no. 12, p. 104-107-
dcterms.isPartOf建筑科学 (Building science)-
dcterms.issued2012-12-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryVoR alloweden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Zheng_new_reference_models.pdf310.8 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

1,069
Last Week
9
Last month
Citations as of Apr 13, 2025

Downloads

247
Citations as of Apr 13, 2025

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.