Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/5006
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Electrical Engineering | - |
dc.creator | Wang, Y | - |
dc.creator | Xiao, L | - |
dc.creator | Wang, D | - |
dc.creator | Jin, W | - |
dc.date.accessioned | 2014-12-11T08:25:26Z | - |
dc.date.available | 2014-12-11T08:25:26Z | - |
dc.identifier.issn | 0146-9592 | - |
dc.identifier.uri | http://hdl.handle.net/10397/5006 | - |
dc.language.iso | en | en_US |
dc.publisher | Optical Society of America | en_US |
dc.rights | © 2006 Optical Society of America. This paper was published in Optics Letters and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://www.opticsinfobase.org/ol/abstract.cfm?URI=ol-31-23-3414. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law. | en_US |
dc.subject | Diffraction gratings | en_US |
dc.subject | Laser beams | en_US |
dc.subject | Optical fibers | en_US |
dc.subject | Strain | en_US |
dc.title | Highly sensitive long-period fiber-grating strain sensor with low temperature sensitivity | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.description.otherinformation | Author name used in this publication: Yi-Ping Wang | en_US |
dc.description.otherinformation | Author name used in this publication: D. N. Wang | en_US |
dc.identifier.spage | 3414 | - |
dc.identifier.epage | 3416 | - |
dc.identifier.volume | 31 | - |
dc.identifier.issue | 23 | - |
dc.identifier.doi | 10.1364/OL.31.003414 | - |
dcterms.abstract | A long-period fiber-grating sensor with a high strain sensitivity of −7.6 pm/με and a low temperature sensitivity of 3.91 pm/°C is fabricated by use of focused CO₂ laser beam to carve periodic grooves on a large- mode-area photonic crystal fiber. Such a strain sensor can effectively reduce the cross-sensitivity between strain and temperature, and the temperature-induced strain error obtained is only 0.5 με/°C without using temperature compensation. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Optics letters, 1 Dec. 2006, v. 31, no. 23, p. 3414-3416 | - |
dcterms.isPartOf | Optics letters | - |
dcterms.issued | 2006-12-01 | - |
dc.identifier.isi | WOS:000242102500004 | - |
dc.identifier.scopus | 2-s2.0-33845942258 | - |
dc.identifier.eissn | 1539-4794 | - |
dc.identifier.rosgroupid | r31854 | - |
dc.description.ros | 2006-2007 > Academic research: refereed > Publication in refereed journal | - |
dc.description.oa | Version of Record | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | VoR allowed | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Wang_Highly_sensitive_long.pdf | 296.19 kB | Adobe PDF | View/Open |
Page views
192
Last Week
3
3
Last month
Citations as of Apr 14, 2025
Downloads
561
Citations as of Apr 14, 2025
SCOPUSTM
Citations
260
Last Week
1
1
Last month
2
2
Citations as of May 8, 2025
WEB OF SCIENCETM
Citations
213
Last Week
0
0
Last month
3
3
Citations as of May 8, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.