Title: | Feasibility investigation of the low energy consumption cooling mode with ground heat exchanger and terminal radiator | Authors: | Man, Y Yang, H Qu, Y Fang, Z |
Issue Date: | 2015 | Source: | Procedia engineering, 2015, v. 121, p. 423-429 | Abstract: | Due to its huge heat capacity, ground can provide heat source in winter and heat sink in summer as the so called shallow geothermal energy, which is mainly utilized by the ground coupled heat pump system. In fact, free cooling can be provided by circulating water between the ground heat exchanger (GHE) and the indoor terminal directly. Recently, radiator for cooling developed rapidly due to it possesses high energy efficiency and comfortable level, however, condensation arises if entering water temperature is lower than dew point of the ambient air. Therefore, this study proposes a low energy consumption cooling mode by combining the GHE and the terminal radiator to utilize the ground cooling directly and to prevent the condensation problem of terminal radiator. The simulation model of this novel mode is established, and the feasibility of this low energy consumption cooling mode is analyzed based on simulation results. | Keywords: | Cooling mode Ground heat exchanger Low energy consumption Terminal radiator |
Publisher: | Elsevier | Journal: | Procedia engineering | ISSN: | 1877-7058 | DOI: | 10.1016/j.proeng.2015.08.1088 | Description: | 9th International Symposium on Heating, Ventilation and Air Conditioning, ISHVAC 2015 Joint with the 3rd International Conference on Building Energy and Environment, COBEE 2015, 12-15 July 2015 | Rights: | © 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). The following publication Man, Y., Yang, H., Qu, Y., & Fang, Z. (2015). Feasibility investigation of the low energy consumption cooling mode with ground heat exchanger and terminal radiator. Procedia engineering, 121, 423-429 is available at https://doi.org/10.1016/j.proeng.2015.08.1088 |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Man_Feasibility_investigation_low.pdf | 429.62 kB | Adobe PDF | View/Open |
Page views
112
Last Week
1
1
Last month
Citations as of Sep 22, 2024
Downloads
85
Citations as of Sep 22, 2024
SCOPUSTM
Citations
9
Last Week
0
0
Last month
Citations as of Sep 26, 2024
WEB OF SCIENCETM
Citations
3
Last Week
0
0
Last month
Citations as of Jun 20, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.