Title: | Effects of luminance combinations on the characteristics of the global flash multifocal electroretinogram (mfERG) | Authors: | Lung, JCY Chan, HHL |
Issue Date: | Aug-2010 | Source: | Graefe's archive for clinical and experimental ophthalmology, Aug. 2010, v. 248, no. 8, p. 1117-1125 | Abstract: | Purpose: This study aims to ascertain the characteristics of the response triggered by the global flash multifocal electroretinogram (MOFO mfERG) under various combinations of global and focal flash luminance, and to determine the optimal conditions for this measurement. Methods: Ten normal subjects with mean age 23.2 yrs (± 1.14 yrs) were recruited for the MOFO mfERG measurement. The visual stimulation consisted of four video frames (stimulus frame with 103 scaled hexagonal focal flashes, followed by a dark frame, a global flash and then another dark frame). The focal and global flash intensities were varied independently for four levels (50, 100, 200 and 400 cd/m 2). The subjects then underwent measurements with sixteen combinations of focal and global flash luminance. The direct component (DC) and induced component (IC) of the MOFO mfERG were grouped into central and peripheral regions for analysis. Results: The central and peripheral DC amplitude increased with the focal flash luminance under constant global flash luminance. Moreover, the proportion of the global flash and focal flash intensity was shown to be important to achieve an optimal IC response. When the ratio of global flash luminance to focal flash luminance (g/f ratio) was kept at about 2:1, the central and peripheral IC amplitude reached the peak value, and further increasing the global flash luminance would not enhance the IC response magnitude. The implicit time of both central and peripheral DC generally decreased with the increase of g/f ratio. However, the implicit time of central and peripheral IC increased with the g/f ratio. Conclusion: The g/f ratio is important in the MOFO mfERG paradigm, since the DC and IC responses change with this ratio. In order to obtain both optimal DC and IC responses, a g/f ratio of 1:1 with focal flash luminance between 100 cd/m 2 and 200 cd/m 2 would be recommended. As the global flash mfERG paradigm is studying the interaction triggered by both flashes, the g/f ratio is a vital parameter for measurement in future studies. | Keywords: | Adaptation Global flash Luminance Multifocal electroretinogram |
Publisher: | Springer | Journal: | Graefe's archive for clinical and experimental ophthalmology | ISSN: | 0721-832X | EISSN: | 1435-702X | DOI: | 10.1007/s00417-010-1346-5 | Rights: | © Springer-Verlag 2010 This is a post-peer-review, pre-copyedit version of an article published in Graefe's Archive for Clinical and Experimental Ophthalmology . The final authenticated version is available online at: https://doi.org/10.1007/s00417-010-1346-5. |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
a0764-n14_1618.pdf | Pre-Published version | 901.52 kB | Adobe PDF | View/Open |
Page views
63
Last Week
0
0
Last month
Citations as of Jun 4, 2023
Downloads
22
Citations as of Jun 4, 2023
SCOPUSTM
Citations
6
Last Week
0
0
Last month
0
0
Citations as of Jun 1, 2023
WEB OF SCIENCETM
Citations
5
Last Week
0
0
Last month
0
0
Citations as of Jun 1, 2023

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.