Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/24628
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineering-
dc.creatorMui, KW-
dc.creatorHui, PS-
dc.creatorWong, LT-
dc.date.accessioned2015-06-23T09:08:59Z-
dc.date.available2015-06-23T09:08:59Z-
dc.identifier.issn1420-326X-
dc.identifier.urihttp://hdl.handle.net/10397/24628-
dc.language.isoenen_US
dc.publisherSAGE Publicationsen_US
dc.rightsThis is the accepted version of the publication Mui KW, (Hui PS), Wong LT., Diagnostics of unsatisfactory indoor air quality in air conditioned workplaces, Indoor Built and Environment (Volume 20 and issue 3) pp. 313-320. Copyright © 2016 (The Author(s)). DOI: 10.1177/1420326X11400880.en_US
dc.subjectEnvironmental diagnosisen_US
dc.subjectIAQ indexen_US
dc.subjectIndoor air qualityen_US
dc.subjectLikelihood ratiosen_US
dc.subjectRepresentative pollutantsen_US
dc.subjectScreening testen_US
dc.titleDiagnostics of unsatisfactory indoor air quality in air-conditioned workplacesen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage313-
dc.identifier.epage320-
dc.identifier.volume20-
dc.identifier.issue3-
dc.identifier.doi10.1177/1420326X11400880-
dcterms.abstractThis study examines a screening process for environmental diagnosis of indoor air quality (IAQ) problems in air-conditioned office buildings. Diagnosis of IAQ problems in relation to complaints of environmental health effects has not been identified as a precise science and this paper proposes an evaluation tool to address this need. An "IAQ index", the average fractional dose of a set of three representative indoor pollutants, has been developed for this purpose, to be used as a screening parameter for detecting the unsatisfactory factors affecting the IAQ in an air-conditioned office. The wide-ranging set of prescribed IAQ measurements for these investigations can be prohibitive due to complexity, cost and time period taken to obtain results. In this study, a 5-level screening strategy based on the IAQ index to quantify the likelihood of unsatisfactory IAQ in air-conditioned workplaces is being proposed. The proposed assessment tool would be a useful protocol for policymakers and professionals to evaluate the relative environmental performance of office spaces and to investigate any IAQ problem. A proposed set of three measurements are used to inform decision whether to take any further action (more measurements or remedial measures) to allow early diagnosis of IAQ problems in air-conditioned offices to satisfy existing Hong Kong IAQ standards.-
dcterms.accessRightsopen access-
dcterms.bibliographicCitationIndoor and built environment, 1 June 2011, v. 20, no. 3, p. 313-320-
dcterms.isPartOfIndoor and built environment-
dcterms.issued2011-06-01-
dc.identifier.isiWOS:000292322800003-
dc.identifier.scopus2-s2.0-79960133042-
dc.identifier.eissn1423-0070-
dc.identifier.rosgroupidr55992-
dc.description.ros2010-2011 > Academic research: refereed > Publication in refereed journal-
dc.description.oaAccepted Manuscript-
dc.identifier.FolderNumbera0680-n19-
dc.identifier.SubFormID911-
dc.description.fundingSourceOthers-
dc.description.fundingTextThe Hong Kong Polytechnic University (GYG51, GYX1Y)-
dc.description.pubStatusPublished-
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
WongLT_803J1FP_IAQ_DiagT_20100226_IBE_NoTrack1Tracka.pdfPre-Published version702.22 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

126
Last Week
1
Last month
Citations as of Mar 24, 2024

Downloads

88
Citations as of Mar 24, 2024

SCOPUSTM   
Citations

4
Last Week
0
Last month
0
Citations as of Mar 28, 2024

WEB OF SCIENCETM
Citations

4
Last Week
0
Last month
0
Citations as of Mar 28, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.