Please use this identifier to cite or link to this item:
                
				
				
				
       http://hdl.handle.net/10397/24628
				
				| DC Field | Value | Language | 
|---|---|---|
| dc.contributor | Department of Building Services Engineering | - | 
| dc.creator | Mui, KW | - | 
| dc.creator | Hui, PS | - | 
| dc.creator | Wong, LT | - | 
| dc.date.accessioned | 2015-06-23T09:08:59Z | - | 
| dc.date.available | 2015-06-23T09:08:59Z | - | 
| dc.identifier.issn | 1420-326X | - | 
| dc.identifier.uri | http://hdl.handle.net/10397/24628 | - | 
| dc.language.iso | en | en_US | 
| dc.publisher | SAGE Publications | en_US | 
| dc.rights | This is the accepted version of the publication Mui KW, (Hui PS), Wong LT., Diagnostics of unsatisfactory indoor air quality in air conditioned workplaces, Indoor Built and Environment (Volume 20 and issue 3) pp. 313-320. Copyright © 2016 (The Author(s)). DOI: 10.1177/1420326X11400880. | en_US | 
| dc.subject | Environmental diagnosis | en_US | 
| dc.subject | IAQ index | en_US | 
| dc.subject | Indoor air quality | en_US | 
| dc.subject | Likelihood ratios | en_US | 
| dc.subject | Representative pollutants | en_US | 
| dc.subject | Screening test | en_US | 
| dc.title | Diagnostics of unsatisfactory indoor air quality in air-conditioned workplaces | en_US | 
| dc.type | Journal/Magazine Article | en_US | 
| dc.identifier.spage | 313 | - | 
| dc.identifier.epage | 320 | - | 
| dc.identifier.volume | 20 | - | 
| dc.identifier.issue | 3 | - | 
| dc.identifier.doi | 10.1177/1420326X11400880 | - | 
| dcterms.abstract | This study examines a screening process for environmental diagnosis of indoor air quality (IAQ) problems in air-conditioned office buildings. Diagnosis of IAQ problems in relation to complaints of environmental health effects has not been identified as a precise science and this paper proposes an evaluation tool to address this need. An "IAQ index", the average fractional dose of a set of three representative indoor pollutants, has been developed for this purpose, to be used as a screening parameter for detecting the unsatisfactory factors affecting the IAQ in an air-conditioned office. The wide-ranging set of prescribed IAQ measurements for these investigations can be prohibitive due to complexity, cost and time period taken to obtain results. In this study, a 5-level screening strategy based on the IAQ index to quantify the likelihood of unsatisfactory IAQ in air-conditioned workplaces is being proposed. The proposed assessment tool would be a useful protocol for policymakers and professionals to evaluate the relative environmental performance of office spaces and to investigate any IAQ problem. A proposed set of three measurements are used to inform decision whether to take any further action (more measurements or remedial measures) to allow early diagnosis of IAQ problems in air-conditioned offices to satisfy existing Hong Kong IAQ standards. | - | 
| dcterms.accessRights | open access | - | 
| dcterms.bibliographicCitation | Indoor and built environment, 1 June 2011, v. 20, no. 3, p. 313-320 | - | 
| dcterms.isPartOf | Indoor and built environment | - | 
| dcterms.issued | 2011-06-01 | - | 
| dc.identifier.isi | WOS:000292322800003 | - | 
| dc.identifier.scopus | 2-s2.0-79960133042 | - | 
| dc.identifier.eissn | 1423-0070 | - | 
| dc.identifier.rosgroupid | r55992 | - | 
| dc.description.ros | 2010-2011 > Academic research: refereed > Publication in refereed journal | - | 
| dc.description.oa | Accepted Manuscript | - | 
| dc.identifier.FolderNumber | a0680-n19 | - | 
| dc.identifier.SubFormID | 911 | - | 
| dc.description.fundingSource | Others | - | 
| dc.description.fundingText | The Hong Kong Polytechnic University (GYG51, GYX1Y) | - | 
| dc.description.pubStatus | Published | - | 
| dc.description.oaCategory | Green (AAM) | en_US | 
| Appears in Collections: | Journal/Magazine Article | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| WongLT_803J1FP_IAQ_DiagT_20100226_IBE_NoTrack1Tracka.pdf | Pre-Published version | 702.22 kB | Adobe PDF | View/Open | 
Page views
175
			Last Week
			
1
		1
			Last month
			
						
					
					
						
							
						
						
					
							
					
								
		
	
			Citations as of Apr 14, 2025
		
	Downloads
136
			Citations as of Apr 14, 2025
		
	SCOPUSTM   
 Citations
		
		
		
		
		
				
		
		
		
			5
		
		
		
				
		
		
		
		
	
			Last Week
			
0
		0
			Last month
			
0
	0
			Citations as of Oct 31, 2025
		
	WEB OF SCIENCETM
 Citations
		
		
		
		
		
				
		
		
		
			5
		
		
		
				
		
		
		
		
	
			Last Week
			
0
		0
			Last month
			
0
	0
			Citations as of Oct 30, 2025
		
	
	Google ScholarTM
		
		
   		    Check
	Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.