Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/2357
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Health Technology and Informatics | - |
dc.creator | Zheng, YP | - |
dc.creator | Lu, MH | - |
dc.creator | Wang, Q | - |
dc.date.accessioned | 2014-12-11T08:29:06Z | - |
dc.date.available | 2014-12-11T08:29:06Z | - |
dc.identifier.issn | 0041-624X | - |
dc.identifier.uri | http://hdl.handle.net/10397/2357 | - |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | Ultrasonics © 2006 Elsevier B.V. The journal web site is located at http://www.sciencedirect.com. | en_US |
dc.subject | Ultrasound | en_US |
dc.subject | Biomicroscopy | en_US |
dc.subject | Elasticity imaging | en_US |
dc.subject | Elastomicroscopy | en_US |
dc.subject | Water jet | en_US |
dc.subject | Indentation | en_US |
dc.subject | Ultrasound indentation | en_US |
dc.subject | Osmotic pressure | en_US |
dc.subject | Triphasic model | en_US |
dc.subject | Articular cartilage | en_US |
dc.title | Ultrasound elastomicroscopy using water jet and osmosis loading : potentials for assessment for articular cartilage | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.identifier.spage | e203 | - |
dc.identifier.epage | e209 | - |
dc.identifier.volume | 44 | - |
dc.identifier.doi | 10.1016/j.ultras.2006.06.008 | - |
dcterms.abstract | Research in elasticity imaging typically relies on 1–10 MHz ultrasound. Elasticity imaging at these frequencies can provide strain maps with a resolution in the order of millimeters, but this is not sufficient for applications to skin, articular cartilage, or other fine structures. In this paper, we introduced two methods of ultrasound elastomicroscopy using water jet and osmosis loading for imaging the elasticity of biological soft tissues with high resolutions. In the first system, the specimens were compressed using water jet compression. A water jet was used to couple a focused 20 MHz ultrasound beam into the specimen and meanwhile served as a “soft” indenter. Because there was no additional attenuation when propagating from the ultrasound transducer to the specimen, the ultrasound signal with high signal-to-noise ratio could be collected from the specimens simultaneously with compressing process. The compression was achieved by adjusting the water flow. The pressure measured inside the water pipe and that on the specimen surface was calibrated. This system was easily to apply C-scan over sample surfaces. Experiments on the phantoms showed that this water jet indentation method was reliable to map the tissue stiffness distribution. Results of 1D and 2D scanning on phantoms with different stiffness are reported. In the second system, we used osmotic pressure caused by the ion concentration change in the bathing solutions for the articular cartilage to deform them. When bovine articular cartilage specimens were immerged in solutions with different salt concentration, a 50 MHz focused ultrasound beam was used to monitor the dynamic swelling or shrinkage process. Results showed that the system could reliably map the strain distribution induced by the osmotic loading. We extract intrinsic layered material parameters of the articular cartilage using a triphasic model. In addition to biological tissues, these systems have potential applications for the assessment of bioengineered tissues, biomaterials with fine structures, or some engineering materials. Further studies are necessary to fully realize the potentials of these two new methods. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Ultrasonics, 22 Dec. 2006, v. 44, supp. 1, p. e203-e209 | - |
dcterms.isPartOf | Ultrasonics | - |
dcterms.issued | 2006-12-22 | - |
dc.identifier.isi | WOS:000248802400041 | - |
dc.identifier.scopus | 2-s2.0-33845692454 | - |
dc.identifier.eissn | 1874-9968 | - |
dc.identifier.rosgroupid | r30487 | - |
dc.description.ros | 2006-2007 > Academic research: refereed > Publication in refereed journal | - |
dc.description.oa | Accepted Manuscript | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Zheng et al Ultrasonics 2006 Noncontact Ultrasound Elastomicroscopy.pdf | Pre-published version | 367.45 kB | Adobe PDF | View/Open |
Page views
120
Last Week
3
3
Last month
Citations as of Oct 1, 2023
Downloads
164
Citations as of Oct 1, 2023
SCOPUSTM
Citations
10
Last Week
0
0
Last month
0
0
Citations as of Sep 28, 2023
WEB OF SCIENCETM
Citations
8
Last Week
0
0
Last month
0
0
Citations as of Sep 28, 2023

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.