Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/2322
DC Field | Value | Language |
---|---|---|
dc.contributor | Department of Health Technology and Informatics | - |
dc.creator | Huang, YP | - |
dc.creator | Zheng, YP | - |
dc.creator | Leung, SF | - |
dc.creator | Mak, AFT | - |
dc.date.accessioned | 2014-12-11T08:29:03Z | - |
dc.date.available | 2014-12-11T08:29:03Z | - |
dc.identifier.issn | 0909-752X | - |
dc.identifier.issn | 1600-0846 | - |
dc.identifier.uri | http://hdl.handle.net/10397/2322 | - |
dc.language.iso | en | en_US |
dc.publisher | Blackwell Munksgaard | en_US |
dc.rights | Copyright © Blackwell Munksgaard 2006. The definitive version is available at www3.interscience.wiley.com | en_US |
dc.subject | Radiotherapy | en_US |
dc.subject | Skin | en_US |
dc.subject | Fibrosis | en_US |
dc.subject | High frequency ultrasound | en_US |
dc.subject | Ultrasonic tissue characterization | en_US |
dc.subject | Ultrasonic properties | en_US |
dc.subject | Reliability | en_US |
dc.title | Reliability of measurement of skin ultrasonic properties in vivo : a potential technique for assessing irradiated skin | en_US |
dc.type | Journal/Magazine Article | en_US |
dc.description.otherinformation | Author name used in this publication: Y. P. Huang | en_US |
dc.description.otherinformation | Author name used in this publication: Y. P. Zheng | en_US |
dc.description.otherinformation | Author name used in this publication: A. F. T. Mak | en_US |
dc.description.otherinformation | Author name used in this publication: S. F. Leung | en_US |
dc.identifier.spage | 55 | - |
dc.identifier.epage | 61 | - |
dc.identifier.volume | 13 | - |
dc.identifier.issue | 1 | - |
dc.identifier.doi | 10.1111/j.1600-0846.2006.00191.x | - |
dcterms.abstract | Background/aims: Quantitative and objective technique to assess radiation-induced tissue fibrosis is important for clinicians to estimate the efficiency of radiotherapeutic schemes. It has been widely reported that ultrasonic properties are sensitive to changes of acoustic scatterers in biological tissues. Therefore, measurement of ultrasonic properties may serve as a potential assessment technique for irradiated skins. The aim of the present study is to investigate the reliability of such measurement so as to evaluate its potentials for future clinical applications. | - |
dcterms.abstract | Methods: Ultrasonic parameters including attenuation slope (β), integrated attenuation (IA) and integrated backscatter (IBS) were measured for the frequency range of 10-25MHz from echographic signals of the forearm and neck dermis of 20 normal subjects in vivo. The intra- and inter-rater reliability of measurement was assessed in 10 normal subjects using intra-class correlation coefficients (ICC) and Bland-Altman test. | - |
dcterms.abstract | Results: The intra- and inter-rater measurement was demonstrated to be reliable as indicated by high ICC values generally larger than 0.80. In addition, the ultrasonic parameters could successfully differentiate the skins in the neck and forearm regions. | - |
dcterms.abstract | Conclusion: The measurement provided reliable information on the ultrasonic properties of the skins and could be potentially applied to comparative clinical trials to assess the late effects of radiotherapy on skins. | - |
dcterms.accessRights | open access | en_US |
dcterms.bibliographicCitation | Skin research and technology, Feb. 2007, v. 13, no. 1, p. 55-61 | - |
dcterms.isPartOf | Skin research and technology | - |
dcterms.issued | 2007-02 | - |
dc.identifier.isi | WOS:000243637800009 | - |
dc.identifier.scopus | 2-s2.0-33846549496 | - |
dc.identifier.pmid | 17250533 | - |
dc.identifier.rosgroupid | r32487 | - |
dc.description.ros | 2006-2007 > Academic research: refereed > Publication in refereed journal | - |
dc.description.oa | Author’s Original | en_US |
dc.identifier.FolderNumber | OA_IR/PIRA | en_US |
dc.description.pubStatus | Published | en_US |
dc.description.oaCategory | Green (AO) | en_US |
Appears in Collections: | Journal/Magazine Article |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Huang et al Reliability of Measurement of Skin Ultrasonic Properties.pdf | Preprint version | 421.96 kB | Adobe PDF | View/Open |
Page views
206
Last Week
1
1
Last month
Citations as of Apr 14, 2025
Downloads
227
Citations as of Apr 14, 2025
SCOPUSTM
Citations
20
Last Week
0
0
Last month
0
0
Citations as of May 8, 2025
WEB OF SCIENCETM
Citations
17
Last Week
1
1
Last month
1
1
Citations as of May 8, 2025

Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.