Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/2317
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Health Technology and Informatics-
dc.contributorResearch Institute of Innovative Products and Technologies-
dc.creatorHuang, YP-
dc.creatorZheng, YP-
dc.date.accessioned2014-12-11T08:29:04Z-
dc.date.available2014-12-11T08:29:04Z-
dc.identifier.issn1874-1207-
dc.identifier.urihttp://hdl.handle.net/10397/2317-
dc.language.isoenen_US
dc.publisherBentham Science Publishers Ltd.en_US
dc.rightsThis work is licensed under the Creative Commons Attribution-NonCommercial License (http://creativecommons.org/licenses/by-nc/3.0/).en_US
dc.subjectUltrasounden_US
dc.subjectHigh frequencyen_US
dc.subjectIntravascular ultrasound (IVUS)en_US
dc.subjectArticular cartilageen_US
dc.subjectThicknessen_US
dc.subjectAcoustical propertiesen_US
dc.subjectDegenerationen_US
dc.subjectOsteoarthritisen_US
dc.subjectEnzyme digestionen_US
dc.titleIntravascular ultrasound (IVUS) : a potential arthroscopic tool for quantitative assessment of articular cartilageen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage13-
dc.identifier.epage20-
dc.identifier.volume3-
dc.identifier.doi10.2174/1874120700903010013-
dcterms.abstractConventional ultrasound examination of the articular cartilage performed externally on the body surface around the joint has limited accuracy due to the inadequacy in frequency used. In contrast to this, minimally invasive arthroscopy-based ultrasound with adequately high frequency may be a better alternative to assess the cartilage. Up to date, no special ultrasound transducer for imaging the cartilage in arthroscopic use has been designed. In this study, we introduced the intravascular ultrasound (IVUS) for this purpose. An IVUS system with a catheter-based probe (Ø ≈ 1mm) was used to measure the thickness and surface acoustical reflection of the bovine patellar articular cartilage in vitro before and after degeneration induced by enzyme treatments. Similar measurement was performed using another high frequency ultrasound system (Vevo) with a probe of much larger size and the results were compared between the two systems. The thickness measured using IVUS was highly correlated (r = 0.985, p < 0.001) with that obtained by Vevo. Thickness and surface reflection amplitude measured using IVUS on the enzymatically digested articular cartilage showed changes similar to those obtained by Vevo, which were expectedly consistent with previous investigations. IVUS can be potentially used for the quantitative assessment of articular cartilage, with its ready-to-use arthroscopic feature.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationOpen biomedical engineering journal, 2009, v. 3, p. 13-20-
dcterms.isPartOfOpen biomedical engineering journal-
dcterms.issued2009-
dc.identifier.scopus2-s2.0-76749154447-
dc.identifier.pmid19662152-
dc.identifier.rosgroupidr42361-
dc.description.ros2008-2009 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
2009 TOBEJ - IVUS for articular cartilage.pdf963.24 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

171
Last Week
2
Last month
Citations as of Apr 14, 2024

Downloads

142
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

33
Last Week
0
Last month
0
Citations as of Apr 4, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.