Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/1874
PIRA download icon_1.1View/Download Full Text
Title: Effect of reconstruction and filtering on kinetic parameter estimation bias and reliability for dynamic SPECT : a simulation study
Authors: Wen, L
Eberl, S
Wong, KP
Feng, DD
Bai, J
Issue Date: Feb-2005
Source: IEEE transactions on nuclear science, Feb. 2005, v. 52, no. 1, p. 69-78
Abstract: Dynamic SPECT has the potential to provide absolute physiological parameter estimates. However, the low sensitivity of SPECT typically results in very noisy dynamic SPECT data. Filtering can reduce the noise, but at the expense of degrading the already poor resolution further. The effect of reconstruction parameters, post-reconstruction filtering and resolution recovery on kinetic parameter estimation bias and reliability was systematically investigated. Dynamic projection data were generated using Monte Carlo (MC) simulations of a mathematical brain phantom at 10 different levels of Poisson noise. The projection data were reconstructed with OSEM with varying numbers of iterations and subsets and were filtered with three-dimensional (3-D) Gaussian filters with varying FWHM. Bias and reliability of the main parameters of interest (K₁,V[sub d], and binding potential) for thalamus, cerebellum, and frontal cortex were estimated for the three-compartment model fits to the tissue time-activity curves derived from the reconstructed data. Reliability (standard deviation) of parameter estimates was obtained with the Bootstrap MC technique, which showed good agreement with conventional MC in a subset of data sets, but required only a small fraction of conventional MC computation time. Post-reconstruction filtering increased bias, without improving the reliability of parameter estimates and, hence, no post-reconstruction filtering is recommended. For reconstructions without resolution recovery, an effective number of 40 iterations overall provided the best tradeoff between bias and reliability for the range of noise levels studied. Resolution recovery achieved a modest reduction in bias.
Keywords: Filtering
Image reconstruction
Monte Carlo methods
Quantitative analysis
Single photon emission computed tomography
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE transactions on nuclear science 
ISSN: 0018-9499
EISSN: 1558-1578
DOI: 10.1109/TNS.2005.843622
Rights: © 2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Wen_et_al_Kinetic_Parameter_Estimation.pdf401.76 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

81
Last Week
0
Last month
Citations as of Apr 14, 2024

Downloads

72
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

11
Last Week
0
Last month
0
Citations as of Apr 12, 2024

WEB OF SCIENCETM
Citations

9
Last Week
0
Last month
0
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.