dc.contributorDepartment of Electrical Engineering-
dc.creatorCheng, KWE-
dc.date.accessioned2014-12-11T08:28:39Z-
dc.date.available2014-12-11T08:28:39Z-
dc.identifier.issn0018-9464-
dc.identifier.urihttp://hdl.handle.net/10397/1663-
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineersen_US
dc.rights© 2005 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.en_US
dc.rightsThis material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.en_US
dc.subjectInductoren_US
dc.subjectPower conversionen_US
dc.subjectTransformeren_US
dc.titleModeling of solenoidal transformer for the calculation of leakage inductance using eddy-current reaction fielden_US
dc.typeJournal/Magazine Articleen_US
dc.description.otherinformationAuthor name used in this publication: Ka Wai Eric Chengen_US
dc.identifier.spage1996-
dc.identifier.epage1999-
dc.identifier.volume41-
dc.identifier.issue5-
dc.identifier.doi10.1109/TMAG.2005.846274-
dcterms.abstractThe design of high-frequency power converter is very difficult because the leakage inductance of the transformer affects the performance. With consideration of the high-frequency eddy current, the flux linkage due to the eddy-current reaction field using a proposed summation calculation method is computed. The leakage inductance of a high-frequency transformer is therefore characterized. An optimum design method of the transformer can be obtained. Experimental results confirm the affectivity of the calculation method.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationIEEE transactions on magnetics, May 2005, v. 41, no. 5, p. 1996-1999-
dcterms.isPartOfIEEE transactions on magnetics-
dcterms.issued2005-05-
dc.identifier.isiWOS:000229084200161-
dc.identifier.scopus2-s2.0-22044457773-
dc.identifier.eissn1941-0069-
dc.identifier.rosgroupidr21695-
dc.description.ros2004-2005 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Modeling of solenoidal transformer for calculation of leakage inductance_05.pdf317.64 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

115
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

341
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

5
Last Week
0
Last month
0
Citations as of Apr 26, 2024

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.